Electrical connection
The machine is supplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket with a
30mA residual current operated device. The socket must be protected
with a 16A delay action fuse on the mains side.
KRÄNZLE 160 TS T - 230 Volt 50 Hz
KRÄNZLE 195 TS T - 230 Volt 50 Hz
When using an extension cable, this must have an earthed lead which
is properly connected to the socket. The conductors in the extension
cable must have a minimum cross section of 1.5 mm². Plug connec-
tions must be of a spray-proof design, and may not be located on a wet
floor.
(with extension cables of more than 10 m - 2.5 mm
2
)
CAUTION !
The use of extension cables which are too long may lead to malfunctions and start
up difficulty.
When using a cable drum, always keep the cable wound as far as possible.