Electrical connection
The machine is supplied with an electrical power cable with plug.
The mains plug must be tted to a standard grounded socket with
a 30mA residual current operated device. The socket must be
protected with a 15A delay action fuse on the mains side.
KRÄNZLE K 1622 115 Volt / 60 Hz
When using an extension cable, this must have an earthed lead
which is properly connected to the socket. The conductors in the
extension cable must have a minimum cross section of 14 AWG.
Plug connections must be of a spray-proof design, and may not be
located on a wet oor.
(with extension cables of more than 10 m - 12 AWG )
CAUTION !
The use of extension cables which are too long may lead to malfunctions and
start up difculty.
When using a cable drum, always keep the cable wound as far as possible.