EasyManua.ls Logo

KROHNE OPTIMASS 1000 Series User Manual

KROHNE OPTIMASS 1000 Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OPTIMASS / 300 / 010
11000000 SSeerriieess TTwwiinn SSttrraaiigghhtt TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
22000000 SSeerriieess TTwwiinn SSttrraaiigghhtt TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
33000000 SSeerriieess SSiinnggllee ZZ TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
44000000 SSeerriieess TTwwiinn UU TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
77000000 SSeerriieess SSiinnggllee SSttrraaiigghhtt TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
88000000kk SSeerriieess TTwwiinn UU TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
88000000//99000000 SSeerriieess TTwwiinn UU TTuubbee CCoorriioolliiss MMaassss FFlloowwmmeetteerr
OOPPTTIIGGAASS 44000000
OOPPTTIIGGAASS 55000000
MMFFCC 330000 MMaassss FFllooww CCoonnvveerrtteerr
Guidelines for the use of Coriolis meters in hazardous areas
AD OPTIMASS 300_010 Haz Areas Rev 01.qxp 05/03/2014 13:24 Page 1
Question and Answer IconNeed help?

Do you have a question about the KROHNE OPTIMASS 1000 Series and is the answer not in the manual?

KROHNE OPTIMASS 1000 Series Specifications

General IconGeneral
TypeCoriolis Mass Flow Meter
Measurement PrincipleCoriolis
Pressure RatingUp to 100 bar
Output Signals4-20 mA, Pulse, Frequency
Housing MaterialStainless Steel
Accuracy±0.1% of rate
Repeatability±0.05% of rate
Communication ProtocolsHART
Power Supply24 V DC
Protection ClassIP67
Tube MaterialStainless steel
ApprovalsATEX, IECEx

Summary

1. Introduction

1.1 General

Overview of OPTIMASS/OPTIGAS flowmeter systems and converters, including configurations.

1.2 MFC 300F & MFC 300F T6

Details on MFC 300F and MFC 300F T6 mass flow converters and their specifications.

1.3 OPTIMASS 1000 / 1010C / 1300C

Intrinsically safe protection types for OPTIMASS 1000, 1010C, and 1300C series.

1.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6

Intrinsically safe protection for OPTIMASS 1000 T6, 1010C T6, and 1300C T6 series.

1.5 OPTIMASS 2000 / 2010C / 2300C

Intrinsically safe protection for OPTIMASS 2000, 2010C, and 2300C series.

1.6 OPTIMASS 3000 / 3010C / 3300C

Intrinsically safe protection for OPTIMASS 3000, 3010C, and 3300C series.

1.7 OPTIMASS 4000 / 4010C / OPTIGAS 4000 / 4010C

Intrinsically safe protection for OPTIMASS/OPTIGAS 4000 and 4010C series.

1.8 OPTIGAS 5000 / 5010C / 5300C

Intrinsically safe protection for OPTIGAS 5000, 5010C, and 5300C series.

1.9 OPTIMASS 7000 / 7010C / 7300C

Intrinsically safe protection for OPTIMASS 7000, 7010C, and 7300C series.

1.10 OPTIMASS 8000k / 8010kC / 8300kC

Intrinsically safe protection for OPTIMASS 8000k, 8010kC, and 8300kC series.

2 TEMPERATURE LIMITS

3 CONNECTION OF SEPARATED SYSTEMS

4 ELECTRICAL CONNECTIONS

5 SERVICE AND MAINTENANCE

Related product manuals