EasyManuals Logo

KROHNE OPTIMASS 7400C User Manual

KROHNE OPTIMASS 7400C
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
2 SPECIAL CONDITIONS
16
OPTIMASS / 400
www.krohne.com 10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
2.5.7 OPTIMASS 3000F / 3400C
OPTIMASS 3000F
OPTIMASS 3400C with aluminium converter housing
VE ab c...m n p...w
01, 03 or 04 1 or 2
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+55 150 T3 - T1 T165
-40...+60 145 T3 - T1 T155
-40...+65 70 T6 - T1 T80
85 T5 - T1 T95
120 T4 - T1 T130
130 T3 - T1 T160
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
VE ab c...m n p...w
01, 03 or 04 0
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+50 150 T3 - T1 T165
-40...+55 115 T4 - T1 T130
-40...+60 80 T5 - T1 T95
90 T4 - T1 T105
-40...+65 65 T6 - T1 T80
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KROHNE OPTIMASS 7400C and is the answer not in the manual?

KROHNE OPTIMASS 7400C Specifications

General IconGeneral
BrandKROHNE
ModelOPTIMASS 7400C
CategoryAccessories
LanguageEnglish

Related product manuals