EasyManua.ls Logo

Krups KP 5000 - Heating Up Time Test; Fluid System Priming

Krups KP 5000
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F U N C T I O N T E S T S
Heatinguptime
Priming offluidsystem
If the heating up
time is more than
40 sec., change the main
pcb.
1. Plugintomainsandpresspower
button.
2. Checktheheatinguptime(timeuntil
powerbuttonstopsblinking).The
timemustbenotmorethan40sec.
Prime the fluid sys-
tem before pressure
test and flow rate meas-
urement.
3. Checkresp.fillwatertank.
4. Placearecipientunderoutlet.
5. Setselectionlever atpositions
(
(cold)and
)
(hot)separatelyfor
about10sec.toprimethefluid
system.

Table of Contents

Related product manuals