Uninterruptible Power Systems
single phase 6/10KVA
Operation Manual

Questions and Answers

  • D
    Donald GrahamAug 17, 2025
    What to do if my KStar UPS has abnormal backup time?
    • J
      Jill MahoneyAug 17, 2025
      If your KStar UPS has an abnormal backup time, it may be because the battery is not fully charged or the battery is bad. To address this, charge the battery for 8 hours when AC is normal, then test the backup time again.
  • L
    Lori CortezAug 20, 2025
    What to do if my KStar 10kVA buzzer beeps twice every second and LCD shows “output overload”?
    • M
      Marvin CoxAug 20, 2025
      If your KStar UPS is beeping twice every second and the LCD displays “output overload”, it means the UPS is overloaded. To resolve this, disconnect some of the connected devices to reduce the load.
  • N
    Nicole BoltonAug 22, 2025
    Why KStar 10kVA UPS doesn’t start after pressing On button?
    • D
      diamond37Aug 23, 2025
      If your KStar UPS doesn't start after pressing the On button, it could be due to two reasons: either the On button wasn't pressed long enough, or the UPS is overloaded. To fix this, press and hold the On button for one second. If that doesn't work, disconnect all loads and try restarting the UPS.
  • J
    James BondAug 26, 2025
    What to do if my KStar UPS shows fault indicator on and the LCD shows “battery fault”?
    • J
      Jeffrey WilsonAug 26, 2025
      If the fault indicator is on and the LCD shows “battery fault” on your KStar UPS, it could be due to several reasons: * The battery circuit breaker might be off or have a poor connection. * The battery connection might be reversed. To solve this, switch on the breaker and check the battery connections. Also, verify the battery polarity.
  • R
    russellkimAug 28, 2025
    What to do if my KStar 10kVA UPS has long beeps and fault indicator on, the LCD shows over-temperature?
    • A
      angela95Aug 28, 2025
      If your KStar UPS is emitting long beeps, the fault indicator is on, and the LCD shows “over-temperature”, it indicates that the UPS is overheating. Check if there is wind blowing out from fans. Move any objects away from the UPS to improve ventilation. Wait until the UPS becomes cool, and then restart it.
  • A
    aparkerAug 31, 2025
    What to do if my KStar 10kVA UPS has AC normal but AC indicator off, the UPS is in battery mode?
    • J
      Jesse StewartAug 31, 2025
      If the AC power is normal but the AC indicator is off, and the KStar UPS is running in battery mode, it could be due to: * The input circuit breaker being off. * An input power connection problem. To resolve this, switch on the input breaker and check the power connection, redoing it if necessary.
  • H
    Heidi ConleySep 2, 2025
    What to do if my KStar UPS has long beeps and fault indicator on, the LCD shows “output short circuit ”?
    • T
      Terry CowanSep 2, 2025
      If your KStar UPS is emitting long beeps, the fault indicator is on, and the LCD shows “output short circuit”, it means there is a short circuit in the output. You should eliminate the short circuit and then restart the UPS.
  • E
    Edward ThomasSep 5, 2025
    What to do if my KStar 10kVA UPS AC indicator is blinking?
    • J
      jacobonealSep 5, 2025
      If the AC indicator on your KStar UPS is blinking, it indicates that the input AC power is beyond the normal range. Pay attention to the backup time if the UPS is in battery mode.
  • J
    Jay BowersSep 8, 2025
    What to do if my KStar UPS has abnormal sound or smell?
    • N
      Nicole MorseSep 8, 2025
      If you notice an abnormal sound or smell coming from your KStar UPS, shut it down immediately.
  • G
    Greg JonesSep 12, 2025
    What to do if my KStar UPS has no alarm but no output?
    • C
      chenchristopherSep 12, 2025
      If your KStar UPS has no alarm but no output, it indicates an output connection problem. Check the connection and re-do it.

Summary

Safety Instruction

Prohibition

Specific actions prohibited to prevent electric shock and ensure warranty validity.

Safety Notice

Important safety precautions for operating and handling the UPS unit.

Product Introduction

Application

Describes the suitable uses and environments for the UPS system.

Product Range

Outlines the available models and configurations of the UPS system.

System Principle Diagram

Illustrates the internal functional blocks and signal flow of the UPS.

Features

Highlights the key technical characteristics and advanced capabilities of the UPS.

Product Overview

Provides a general description and visual representation of the UPS unit.

Product View

Shows a visual representation of the complete UPS unit.

LCD Operation Instruction

Details how to operate and navigate the UPS using its LCD control panel.

Display Instruction

Explains the different interfaces and information shown on the UPS LCD screen.

Warning Messages

Lists and explains warning messages displayed by the UPS system.

Installation

Unpack Checking

Steps to verify the UPS unit and accessories upon receiving it.

Installation Procedure

Comprehensive guide on how to physically install the UPS unit and its components.

Installation Note

Important considerations and precautions before and during UPS installation.

External Battery Connection

Specific steps for installing external battery connections for extended models.

Connection of Parallel System

Instructions for connecting multiple UPS units in a parallel configuration.

Operation

Working Modes

Explains the different operational states of the UPS (AC, Bypass, Battery, ECO).

AC Mode

Describes operation when AC power is normal and supplied to the load.

Bypass Mode

Details operation when UPS is in bypass, typically due to overload or fault.

Battery Mode

Explains operation when the UPS supplies power from its batteries.

ECO Mode

Describes the energy-saving Economy mode of operation.

Power On

Step-by-step guide for powering on the UPS system safely.

System Parameter Setting

How to configure various operational parameters via the LCD interface.

Start

Procedures for starting the UPS under different conditions, including AC availability.

Manual Battery Testing

Instructions for performing a manual test of the UPS battery performance.

Inverter Shutdown

Steps for safely shutting down the UPS inverter.

Power Off

Procedure for completely powering off the UPS unit.

Working Mode and Transferring

How the UPS switches between different operating modes automatically.

Transfer to Bypass if Overload

Explains the UPS's behavior when the load exceeds its capacity.

Normal Mode to Battery Mode

Describes the transition to battery power when AC input fails.

Go to Bypass Mode due to Over Temperature

How the UPS enters bypass mode due to high internal temperatures.

Output Short Circuit

Procedures for handling and recovering from an output short circuit condition.

UPS Monitoring

Guidance on monitoring UPS status using provided software.

LCD Operation Menu

Detailed guide for navigating and using the UPS's LCD menu system.

Main Menu Switching

How to navigate between main menu options on the LCD.

Submenu Switching

How to navigate and select options within submenus on the LCD.

Priority of Info Displayed on LCD

Explains the display logic and priority of information on the LCD screen.

Maintenance

Fan Maintenance

Guidelines for checking and maintaining the UPS cooling fans.

Battery Maintenance

Procedures for maintaining the UPS battery for optimal performance and lifespan.

Visual Checking

Recommendations for performing visual inspections of the UPS.

UPS Status Checking

Methods for checking the current operational status and indicators of the UPS.

Function Checking

Periodic checks to ensure all UPS functions are operating correctly.

Troubleshooting

Appendix 1. USB Communication Port Definition

Definition of Male Port

Specifies the pinout and function of the USB connector on the UPS.

Appendix 2. Specification

Appendix 3. Option

Appendix 4. UPS Message Table

Running Status Messages

Lists and explains various status codes indicating the UPS's current operating state.

Status Messages

Provides a detailed breakdown of status messages and their corresponding indicators.

Alarm A Messages

Lists and explains critical alarm codes indicating potential faults or issues.

Alarm B Messages

Lists and explains additional alarm codes for system faults and warnings.

KStar 10kVA Specifications

General IconGeneral
Apparent Power10kVA
Output Voltage220/230/240VAC
Efficiency>90%
Operating Temperature0-40°C
Capacity8kW
Output Frequency50/60Hz
Battery TypeSealed Lead-Acid (SLA)