9.3.3 PARAMETER
When air is not requested,
compressor stays in stand by
for this time, then stops
Under this temperature the
system doesn’t stop after
stand by time
Above this temperature it
appear temperature alarm
Above this value electric fan
starts
Above this value compressor
goes in unload mode
Under this value compressor
goes in load mode
Is the time setted between one
maintenance and the next
(protected by key parameter,
that is required every time it is
accessed)
Maintenance hours
resetting
Enter the code key to reset the
maintenance alarm
Only for maintenance
workers
Hours remaining to
maintenance
It shows hours remaining to
the next maintenance / control
9.3.4 STOPPING THE COMPRESSOR
By pressing
for 2 seconds, it appears the following flashing screen:
After 10 seconds, the compressor stops.