EasyManua.ls Logo

Kubota R430 - Page 69

Kubota R430
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Check points
Meas-
ures
Hour meter indicator
Inter-
val
Ref.
pag
e
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 1000
38
Intake air line for air
leaks
check
every
1 year
85
*3
39
AFS (Air flow sen-
sor)
check
every
1 year
85
*3
40 Boost sensor check
every
1 year
85
*3
41
EGR and piping for
gas leak
check
every
1 year
86
*3
42 Radiator system rinse
every
2
years
68
43
Rubber piping relat-
ed oil separator
replace
every
2
years
87
*3
44
Intake hose and in-
tercooler hose
replace
every
2
years
87
*3
45 EGR cooler hose replace
every
2
years
87
*3
IMPORTANT :
Perform the job indicated by at the first operation.
When using biodiesel, be sure to check the maintenance requirements of biodiesel fuel as the intervals will change in some of the
items.
*1 This maintenance is appeared on the meter panel at each specified maintenance hours.
*2 Replace only if necessary.
*3 Consult your local KUBOTA Dealer for this service.
 MAINTENANCE
R430
65

Table of Contents

Related product manuals