Disassembly/Assembly
Replacing
the
Keyboard
Contact
Strips
Position
the
contact
strip
on
the
board.
Be
sure
the
deeper
indent
of
the
contact
is
located
to
the
rear
of
the
key.
The
contacts
are
secured
to
the
board
by
small
and
somewhat
larger
rubber
pegs
that
are
pushed
through
their
respective
mounting
holes
on
the
board.
Be
sure
that
the
rubber
mounting
pegs
line
up
correctly.
Using
a
small
blunt-end
tool
(i.e.
Q-Tip,
toothpick,
etc.),
gently
push
the
mounting
pegs
through
the
holes.
Be
careful
not
to
poke
through
the
mounting
pegs
when
installing
the
contract
strips.
Removing
a
Key
Weight
The
PC88
keyboard
key
weights
are
attached
via
a
rod
that
runs
the
length
of
the
keyboard.
The
rod
is
actually
two
pieces.
The
first
rod
starts
at
low
A
and
extends
to
G#
above
middle
C.
The
second
rod
starts
at
A
above
middle
C
to
High
C.
These
rods
will
be
referred
to
as
the
Bass
and
the
Treble
rod.
The
natural/white
and
sharp/black
key
weights
are
physically
different.
You
will
notice
that
the
sharp
key
weights
are
somewhat
smaller.
Be
sure
to
install
the
key
weights
into
their
appropriate
positions
after
removal.
The
main
components
of
the
weighted-key
action
consist
of
the
following:
the
keys
(88
keys),
two
rods,
key
weights
(88),
key
weight
and
rod
support
bracket
(7,
12
key-
position
and
1,
4
key-position).
To
remove
a
key
weight,
follow
the
instructions
indicated
to
remove
the
Keyboard.
Remove
the
keys
from
the
section
with
the
broken
key
weight.