Pro-Lite Operator’s Manual
Page 41
SPECIFICATIONS
Nominal Power
Requirements
Speed mode, laser
firing
Range mode, laser
firing, backlight on
Idle
Sleep
Power Down
ALERT! (Low voltage)
WARNING! (Low volt)
Battery
Voltage (VDC) Current (ma)
3.0 350
3.0 355
3.0 190
3.0 96
3.0 0.05
2.0 VDC nominal
1.8 VDC nominal
2 each 1.5 VDC nominal, AA size
Alkaline
Operating Temperature
-30 to +60°C (-22 to +140°F)
90% relative humidity @ 37°C non-
condensing
Dimensions
Weight
4.87"L x 5.73"W x 1.92"H
19 oz with batteries
Eye Safety CDRH Class 1 Eye safe