Do you have a question about the Kwikot KwikBoil and is the answer not in the manual?
Unit is designed for interior installation only and is not weatherproof.
Instructions for removing the jacket from all models by unscrewing retaining screws.
All units require a minimum clearance of 50 mm on all sides for servicing.
Details on suspending the Kwikboil using keyhole slots at the back of the unit.
Connect mains cold water supply to the 1/2" BSP inlet fitting, ensuring an isolating valve.
Connect a 15 mm (1/2") pipe to the vent/overflow connection with a continuous fall.
Locates the drain screw on the underside for tank drainage during servicing.
Details on the tap fitting to the threaded tap outlet extension with an 'o' ring seal.
Specifies electrical requirements: 230 Volts AC, 50HZ, Single Phase, and element ratings.
Explains the sequence of events when the unit is switched on for the first time.
Details the sequence where the element heats water, then cools, and the solenoid valve opens.
Describes the cycle of heating, cooling, and element re-energizing based on water draw-off.
Occurs when no water fills the tank; indicates causes like no water or faulty probes/valve.
Occurs when water temperature doesn't change; points to element or connection issues.
Indicates water level is higher than normal, possibly due to a faulty or scaled probe.
Occurs when the thermistor is faulty and not detecting water temperature.
| Type | Electric Water Heater |
|---|---|
| Mounting | Wall Mounted |
| Capacity | 15L |
| Power | 3kW |
| Material | Mild Steel |
| Thermostat | Adjustable |
| Heating Time | Varies based on capacity and power rating |