3-44
Enhancement device setup procedure > Optional device installation
[CONFIDENTIAL]
16
Check height both Bridge Kit (AK-9110) and main unit.
1 Check the height.
Check the color borders between main unit and Bridge Kit for Main Unit (AK-9110). If the borders are in same
line then insert connection pin [A] to hole on AK-9110 [B]. Connect AK-9110 and main unit. Check the position
of pin [A] diameter [C] and hole [B] height [D].
OK: Pin diameter [C] is in between hole height [D].
NG: Pin diameter [C] is out of hole height [D].
2 Check the level.
Check the level with the distance between main unit and AK-9110 [E], [F].
OK: The distance between main unit and AK-9110 [A], [B] are equal.
NG: The distance between main unit and AK-9110 [E], [F] are not equal.
NOTE
If the color borders of main unit and Bridge Kit for Main Unit (AK-9110) are not in same line then height
adjustment is necessary.
[A]
[B]
[C]
[D]
[C]
[C]
[D]
OK
NG NG
[D]
[A]
[B]
[C]
[D]