EasyManua.ls Logo

Kyocera ECOSYS M3145dn - Page 362

Kyocera ECOSYS M3145dn
423 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-14
Troubleshooting > Troubleshooting
Printouts have vertical lines.
Is the slit glass dirty? Clean the slit glass. page 10-2
Dirt on the top edge or back
of the paper.
Is the interior of the machine dirty? Clean the interior of the machine. page 10-3
Part of the image is
periodically faint or shows
white lines.
Select the [System Menu/Counter] key
> [Adjust/Maint.] > [Service Setting] >
[Drum Refresh] > [Yes]
Print on the back of the
sheet is visible on the front.
Set [Prevent Bleed-through] to [On]. page 6-16
page 8-33
Lines appear on ruled lines. Is the paper damp? Replace the paper with new paper. page 3-2
Select the [System Menu/Counter] key
> [Adjust / Maint.] > [Service Setting]
> [Transfer Adj.], and set to
[LineTextPriority].
Part of the image has come
off (poor toner fixation).
Select the [System Menu/Counter] key
> [Adjust / Maint.] > [Service Setting]
> [Fuser Adjustment], and set to [2].
Symptom Checkpoints Corrective Actions
Reference
Page

Table of Contents

Other manuals for Kyocera ECOSYS M3145dn