MANAGER INSTRUCTIONS
AUDITGARD
66E (LGA) Electronic Combination Lock
AuditGard locks are shipped from LA GARD in Factory Default
state without Users or features enabled. Refer to the AuditGard
Setup Instructions (742.049) if Lock settings have not already
been programmed.
Factory Default: The Lock must be in the Factory Default state to
be programmed by the PC software.
Factory mode functions as follows:
1 key – When pressed, will open the Lock.
0 key – When pressed, prompts the AuditGard Setup software
to send the configuration settings to the Lock.
All other keys perform no function.
Setup: AuditGard locks must be programmed using the AuditGard
Setup Software. Once programmed, Manager Combination is
enabled, and MUST be changed to activate
the Lock.
Active: The Manager combination must be changed before any
Manager commands are available.
PROGRAMMABLE LOCK FEATURES
MODES (Multiple Modes may be selected.)
Silent Alarm (Alarm Box Required)
If enabled, this option will send a signal to an outside alarm
system through the LA GARD Alarm Box.
• DualMode
If enabled, two combinations will be required to operate
the Lock.
The Manager and one additional User must be active.
• TimeDelayOverride
If enabled, User 9 can override delay period.
User 9 must be active.
EXTERNAL SIGNALS (Alarm Box Required. Only one External
Signal type may be selected.)
An external input signal to the Alarm Box will either Disable
Opening Only or Disable All Access depending on the selection
programmed for External Signals.
External Signal disables Lock opening with valid combination.
OR External Signal disables Lock opening with valid
combination and all Lock commands.
TIME DELAY
Delay Period 1 - 99 minutes
Open Period 1 - 19 minutes
COMBINATION LENGTH
A combination length from six (6) to nine (9) digits may
be selected.
NOTE: To maintain the VdS Class 2 and EN 1300 Class B
certification when the duress alarm feature is used, a combination
length of 7 digits or longer must be selected.
LOCK USERS
Manager (ID #1)
Open Lock
Change Combination
Enable/Disable Users
Delete Users
Set Time Delay Values
Audit Lock
Users (ID# 2-9)
Open Lock
Change Combination
STANDARD LOCK FEATURES
Wrong Try Penalty
Entry of four (4) consecutive invalid combinations initiates a ve
(5) minute delay penalty.
Lock responses during the penalty period are as follows:
- The LED will flash every ten (10) seconds.
- If any key is pressed, the Lock will ash the LED and beep
three times.
Once the penalty period has ended, two (2) consecutive invalid
combinations will initiate another five (5) minute penalty period.
Low Battery Warning
Repeated audio/visual signals (LED ashes/beeps) during Lock
opening indicate the battery is low and should be
replaced immediately.
If the battery level becomes too low to safely operate the Lock,
pressing any key will initiate the low battery warning.
The battery must be replaced before the Lock will operate.
Dual-Handed
Swing Bolt
Dead Bolt
3750-K
Round Entry
3125
Round Entry
LOCKS
ENTRY DEVICE OPTIONS
8130
(Optional)
3190 Privat
II
(Optional)
Question and Answer IconNeed help?

Do you have a question about the La Gard 3190 Privat and is the answer not in the manual?

La Gard 3190 Privat Specifications

General IconGeneral
BrandLa Gard
Model3190 Privat
CategoryLocks
LanguageEnglish

Summary

Manager Instructions

Lock Types

Details physical lock types: Dual-Handed Swing Bolt and Dead Bolt.

Entry Device Options

Lists available entry device models: 3750-K, 3125, 8130, 3190.

Time Delay Configuration

Configuration options for delay and open periods, up to 99 minutes.

Combination Length

Sets allowed combination lengths from six to nine digits.

Lock User Management

Details Manager (ID #1) and User (ID #2-9) capabilities and permissions.

Programmable Lock Features

Explains features like Silent Alarm, Dual Mode, and Time Delay Override.

External Signal Integration

How external inputs can disable access based on programmed settings.

Standard Lock Features

Details Wrong Try Penalty and Low Battery Warning indicators.

Lock Operating Conventions

Audit Records Overview

Explains audit records, their storage, and retrieval requirements.

Basic Operation Without eKEY

Procedures for entering combinations and opening locks.

Operation With eKEY

Instructions for operating the lock using an eKEY dual token.

Lock Response Indicators

Explains LED and beep signals for standard and additional operations.

Manager Command: Activate User

Steps to activate a user combination after initial setup.

Manager Command: Disable User

Procedure to temporarily disable a user's access.

Manager Command: Delete User

Steps to permanently remove a user from the lock system.

Advanced Manager Commands

Manager Command: Audit Lock

Detailed steps for auditing the lock using software and hardware.

Manager Command: Set Time Delay

Procedures for setting or changing time delay and open periods.

Lock Operations

Instructions for changing combinations, opening locks, and time delay overrides.

Initiate Silent Alarm

Method to trigger a silent alarm by altering the combination.

Battery Maintenance and Replacement

Recommendations for battery replacement and types.