SET-UP
1.Disablethetamp.
2.Therearcoverwindowonthedetectormustbeopenedbeforeanyadjustmentscanbemade.See
Figure16.Presstheflexibleretainingclipagainstthecabletoopenthewindow.
3.GentlyslidetheL/DoperateswitchonthebackofthedetectortoL
(towardstheretainingclip)for
LightOperation.
4.Usea3/32inchhexheadwrenchtoloosenthedetector.Slidethedetectorinoroutuntiltheredspot
issharplyfocusedonaproductabout1/2inchfromthetamppad.Secureinposition.Theyellowlight
ontherear
ofthedetectorwilllight.
Figure16TampInterruptSensorDetail
5.Iftheorangeindicatorisalsolit,usea
1/16inchflatbladescrewdrivertoturnthe
sensitivityadjustmentscrew
counterclockwiseuntiltheorangeindicator
goesout.
6.Usethescrewdrivertoturnthesensitivity
adjustmentscrewclockwiseuntilthe
orangeindicatorjustgoeson.
7.Removetheproductfromin
frontofthe
tamppad.TheyellowLEDontherearofthe
detectormustgooutandthegreenLEDwill
light.Adjustthegainadjustmentif
necessaryandrepeatthisprocedure.
8.Snapthewindowcoverclosedonthe
detector.