In the event that you need assistance for servicing your Ironsoft water softener, please rst contact
the professional contractor who installed the system.
Congratulations on purchasing your new Lancaster IronSoft Water Softener. This unit is designed
to give you many years of trouble free service. When installed in accordance with the following
instructions and if given reasonable care, clear-soft water will be the result. For servicing and future
inspection purposes, please le this booklet with your important documents.
7-FESLX-24B
7-FESLX-32B
7-FESLX-45B
7-FESLX-60B
7-FESLXC-24B
ELECTRONIC IRONSOFT WATER SOFTENER
WITH THE X-FACTOR CONTROL VALVE
PROGRAMMED FOR PRE-FILL BRINING OPTION
INSTALLATION, OPERATING AND
SERVICE MANUAL
I R O N S O F T

Questions and Answers

  • C
    Collin KingAug 11, 2025
    Why does the PC Board on my Lancaster IRONSOFT X- FACTOR Water Dispenser not display the correct time?
    • P
      Philip YorkAug 11, 2025
      If the PC Board on your Lancaster Water Dispenser doesn't display the correct time, it might be due to several reasons: * The power adapter could be plugged into an outlet controlled by a light switch. Use an uninterrupted outlet instead. * A tripped breaker or GFI switch can also cause this. Try resetting them. * There may have been a power outage. In this case, you'll need to reset the time of day. If your PC Board has a battery backup, the battery might be depleted. * Lastly, the PC Board itself could be defective and require replacement.
  • K
    Kelli HerreraAug 23, 2025
    Why is my Lancaster IRONSOFT X- FACTOR Water Dispenser control valve regenerating at the wrong time?
    • J
      jodyschwartzAug 25, 2025
      If your Lancaster Water Dispenser's control valve regenerates at the wrong time of day, consider these potential causes: * A power outage may have occurred. Reset the time of day. If the PC Board has a battery backup, it may be depleted. * The time of day might not be set correctly. Reset it to the correct time. * The regeneration time could be set incorrectly. Reset the regeneration time. * The control valve might be set to “on 0” (immediate regeneration). Check the programming setting and reset to NORMAL (for a delayed regeneration time). * The control valve could be set to “NORMAL + on 0” (delayed and/or immediate). Check the programming setting and reset to NORMAL (for a delayed regeneration time).
  • M
    Mary CohenAug 29, 2025
    How to troubleshoot no display on the Lancaster IRONSOFT X- FACTOR PC board?
    • K
      Kimberly Buckley DVMAug 29, 2025
      If there is no display on the PC Board of your Lancaster Water Dispenser, here are a few things you can check: * Ensure that there is power at the electrical outlet. If not, repair the outlet or use a working one. * Verify that the control valve power adapter is plugged into the outlet and that the power cord end is connected to the PC board connection. If not, plug the power adapter into the outlet or connect the power cord end to the PC Board connection. * Confirm that the power supply is proper and delivering the correct voltage to the PC Board. * The power adapter may be defective and need replacement. * The PC Board itself could be defective and require replacement.
  • K
    Kimberly McdonaldSep 4, 2025
    What does it mean when the time of day flashes on my Lancaster Water Dispenser?
    • W
      William RodriguezSep 4, 2025
      If the time of day is flashing on and off on your Lancaster Water Dispenser, it is likely due to a power outage. Reset the time of day. If the PC Board has a battery back up, the battery may be depleted.
  • R
    Robert HooperNov 16, 2025
    What to do if the display on my Lancaster IRONSOFT X- FACTOR doesn't indicate water flow?
    • A
      Allen AguilarNov 16, 2025
      If the display on your Lancaster Water Dispenser doesn't indicate water is flowing, it could be due to the following reasons: 1. The bypass valve may be in the bypass position. Turn the bypass handles to place the bypass in the service position. 2. The meter might not be connected to the meter connection on the PC Board. Connect the meter to the three-pin connection labeled METER on the PC Board. 3. The meter turbine could be restricted or stalled. Remove the meter and check for rotation or foreign material. 4. The meter wire may not be securely installed into the three-pin connector. Verify the meter cable wires are securely installed into the three-pin connector labeled METER. 5. The meter itself could be defective and need replacement. 6. The PC Board might be defective, requirin...