PAGE 1
INSTALLATION, OPERATING
AND SERVICE MANUAL
PLATINUM LINE LES
ELECTRONIC CITY SOFT PLUS SYSTEM
WITH THE LESCV1 VALVE
In the event that you need assistance for servicing your water conditioner, please rst contact the
professional contractor who installed the system.
Congratulations on purchasing your new Lancaster Water Conditioner. This unit is designed to give
you many years of trouble free service. When installed in accordance with the following instructions
and if given reasonable care, clear-soft water will be the result. For servicing and future inspection
purposes, please le this booklet with your important documents.
7-LESDCATS-75B
7-LESDCATS-100B
7-LESDCATS-150B
7-LESDCATS-200B
7-LESDNS-75B
7-LESDNS-100B
7-LESDNS-150B
7-LESDNS-200B
Question and Answer IconNeed help?

Do you have a question about the Lancaster PLATINUM LINE LES X Factor Series and is the answer not in the manual?

Lancaster PLATINUM LINE LES X Factor Series Specifications

General IconGeneral
BrandLancaster
ModelPLATINUM LINE LES X Factor Series
CategoryWater Dispenser
LanguageEnglish

Summary

General Installation and Service Warnings

Plumbing and Lubrication Warnings

Warnings regarding plumbing support, lubricants, and sealants during installation.

Fittings and Connections Advice

Instructions for assembling fittings, heat from soldering, and avoiding damage to components.

Bypass Valve Operation

Normal Operation Mode

Describes the position for regular water flow through the control valve.

Bypass Operation Mode

Details how to isolate the control valve, supplying untreated water.

Installation Instructions

System Placement and Mineral Addition

Guidance on placing the unit and adding minerals to the tank.

Plumbing Connections

Instructions for connecting inlet, outlet, and drain lines, including air gaps.

Brine Refill and Line Connection

How to connect the brine refill flow control and brine line tubing.

Placing the City Soft Plus into Service

Initial Service Procedure

Steps to place the unit into service, including initial water flow and regeneration start.

System Sanitizing Procedure

Instructions for sanitizing the resin bed with household bleach.

Adjust Hardness, Days Between Regenerations, or Time of Regeneration

Hardness Setting

How to set the water hardness in grains per gallon.

Regeneration Time Setting

Setting the hour and minute for the next scheduled regeneration.

Mineral Tank Assembly Components

Tank Assemblies

Details on tank, pipe, and connector assemblies for different models.

Mineral and Resin Types

List of calcite, carbon, and ion exchange resins with associated part numbers.

Drive Cap Assembly Components

Injector, Injector Cap, Screen and O-Ring Components

Refill Flow Control Assembly Components

Water Meter Components

Drain Line - 3/4" Components

Drain Elbow and DLFC Options

Components like the drain elbow, O-ring, and Drain Line Flow Control (DLFC) options.

Bypass Valve Components

Service Instructions - Drive Assembly

Drive Assembly Removal and Service

Detailed steps for removing and servicing the drive assembly and its components.

Drive Cap Assembly, Piston Service

Refill Flow Control Assembly Service

Injector Cap, Screen, Plug and Injector Service

Water Meter Service

Troubleshooting Procedures

Timer and Display Issues

Solutions for timer not displaying time or displaying incorrect time.

Softening and Regeneration Problems

Troubleshooting for no softening, incorrect regeneration times, and regeneration stalls.

Error Code Resolution

Guidance for resolving specific error codes like 101, 102, 103, and 104.

Control Valve Stalling

Troubleshooting steps for control valve stalling during regeneration.