EasyManua.ls Logo

L&W LW 225 E - Adjust Pressure Maintaining Valve

L&W LW 225 E
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page A - 65
A
LW 225 E / LW 245 B
Version: 19.11.2015
Safety valves
Every pressure stage is equipped with a separate over
pressure safety valve. Safety Valves avoid a non permissible
high pressure at the specific pressure stages and limit
maximum operation pressure of the compressor.
Safety valves are adjusted to:
1st Stage: 14 bar
2nd Stage: 80 bar
3rd Stage: max. final pressure
The adjusted blow-off pressure [bar] of the safety valves is
indicated on their housings.
All safety valves are factory sealed with special L&W safety
seals to avoid manipulation of the limit value settings.
Safety valves with removed seals have to be immediately
checked for the prescribed settings and replaced if
necessary.
The safety valve of the final stage is furthermore equipped
with a knurled screw to be activated once.
Turning the knurled screw clockwise could vent the valve
completely and therefore the final filter housing.
During normal operation conditions, the knurled screw has
to be turned anti-clockwise up to the upper stop. An integrated circlip avoids complete unscrewing.
If a safety valve blows off, it indicates problems with either inlet or outlet valve of the following stage.
Fig. 1 - Safety valve 2nd stage
Fig. 2 - Safety valve 3rd stage
M A I N T E N A N C E A N D S E R V I C E
Note
Replace defective safety valves immediately!