Page A - 78
A
LW 225 E / LW 245 B
Version: 19.11.2015
S T O R A G E
Note
Please check the specific handbook of the petrol engine regarding conservation / storage,
de-conservation and commissioning of the LW 100 B compressors.
i
De-conservation, commissioning
After the compressor has been stored, the following steps are to be taken:
•
If compressor hasn’t been used for longer than 12 months, we strongly recommend an oil
change before any use.
•
Replace intake filter cartridge and check oil level.
•
Clean compressor unit, check for foreign objects.
•
Check condition and tension of V-belts, replace if necessary.
•
Check condition of filling hoses, replace if necessary.
•
Secure hoses against whipping and open filling valves and run compressor for approximately
10 minutes.
•
Check condition of final filter cartridge, replace if necessary.
•
Close filling valves and run compressor up to final pressure.
•
Check safety valve relief pressure of final stage and/or pressure switch setting.
•
Check all connections and pipe work for leaks.
Once all above steps are completed, compressor unit is now ready for use.