4: Configuration Using XML
EDS-MD® Wired IoT Device Gateway Command Reference 26
interface: instance
("Instance" attribute 
is “eth0”, “eth1”, or 
“eth2”)
state enable, disable
bootp enable, disable Default: disable
dhcp enable, disable Default: enable
priority Accepts a priority 
between 0 and 10. A 
lower number signifies 
a higher preference.
ip address <None>, ... Accepts an IP address 
and mask as either: (1) 
IP address only 
(192.168.1.1) gets a 
default mask, (2) CIDR 
(192.168.1.1/24), or (3) 
Explicit mask 
(192.168.1.1 
255.255.255.0).
default gateway <None>, ... Accepts in IP address 
in dotted notation, like 
192.168.1.1.
hostname
domain
dhcp client id
primary dns <None>, ... Accepts in IP address 
in dotted notation, like 
192.168.1.1.
secondary dns <None>, ... Accepts in IP address 
in dotted notation, like 
192.168.1.1.
mtu Default: 1500 bytes
ip ip time to live Default: 64 hops
multicast time to live Default: 1 hops
line:instance
("Instance" attribute 
is a number.)
name
state enable, disable Default: depends on 
instance
protocol none, tunnel Default:
baud rate Default: 9600 bits per 
second
parity even, none, odd Default: none
data bits 7, 8 Default: 8
stop bits 1, 2 Default: 1
flow control none, hardware, 
software
Default: none
Group Name 
(continued)
Group Item Value Name Value Options Additional 
Information