5:  Commands and Levels 
EDS-MD® Wired IoT Device Gateway Command Reference  366 
 
Selects the RSA/DSA certificates by name for the 
SSL client. 
Restores the default protocol as "TCP". 
default tcp keep alive idle time 
Defaults the TCP keep alive idle time. 
default tcp keep alive interval 
Restores the default 45 second connect mode TCP 
keep alive timeout. 
default tcp keep alive probes 
Defaults the TCP keep alive probes. 
Exits to the next higher level. 
initial send binary <binary> 
Sets the host connect tunnel Initial Send text 
allowing for binary characters. <binary> = string in 
binary format that will be sent out the network upon 
connection. Within [] use binary decimal up to 255 
or hex up to 0xFF. 
Sets the host connect tunnel Initial Send text. <text> 
= ascii string that will be sent out the network upon 
connection. 
Removes the remote host address used to establish 
tunneling connections. 
Removes the connect tunnel AES decrypt key. 
Removes the connect tunnel AES encrypt key. 
Clears the RSA/DSA certificate selection. 
Removes the host connect tunnel Initial Send string. 
Removes the remote port used to establish tunnel 
connections. 
Removes the SSH user name. 
Sets the remote port to use for connect mode 
tunneling. <number> = number of the port to use. 
Uses SSH protocol for connect mode tunneling. 
Uses SSL protocol for connect mode tunneling. 
Uses TCP protocol for connect mode tunneling. 
Uses TCP protocol with AES encryption for connect 
mode tunneling. 
Uses Telnet protocol (with IAC) for connect mode 
tunneling. 
Uses UDP protocol for connect mode tunneling. 
Uses UDP protocol with AES encryption for connect 
mode tunneling. 
Shows the current configuration. 
Displays the last 20 commands entered during the 
current CLI session. 
show connection statistics 
Sets the SSH user name for use when establishing 
tunneling connections with other devices. <text> = 
SSH user name. 
tcp keep alive idle time <milliseconds> 
Sets the TCP keep alive idle time. This is the initial 
keep alive timeout. <milliseconds> = timer value, in 
milliseconds. 
tcp keep alive interval <milliseconds> 
Enables TCP keep alive for connect mode tunneling 
and sets the timer. <milliseconds> = timer value, in 
milliseconds.