LARIUS 2 - painting
English
H9
H7
H8
H10
I3
I
ROUTINE MAINTENANCE
Check that all the hose connections are tight.
Clean and, if necessary, replace the worn seals.
Check filters (I1), (I2) and (I3) and replace them when ne-
cessary.
Check the nozzle on the spray gun and clean it.
With the spray gun over the thinner tank, press the trigger
in order to let the thinner circulate during at least five minu-
tes.
If necessary change the thinner and repeat this operation
more times until all the residues of the product will have been
eliminated.
Clean the product hose (H7) by means of a rag and wash
the filters (H8), (H9) and (H10) with the solvent.
After the use of products with a base of polyvinyl alcohol or
of water soluble products, first clean the pump with water
and then let some alcohol circulate through the plant.
If it is foreseen a long period of standstill for
the pump, after the cleaninng let some light
mineral oil circulate in order to protect it against
corrosion.
I2