TROUBLESHOOTING
Solution
Cause
Problem
• The equipment does not suck the
product
• The equipment suck but does not
reach the pressure desired
• When pressing the trigger, the
pressure lowers considerably
• The pressure is normal but the
product is not atomized.
• Leakage from the seal-tightening
screw
• The atomization is imperfect
• Suction filter clogged;
• Suction filter too fine;
• The equipment sucks air;
• Lack of product;
• The equipment sucks air;
• The circulation tap is open;
• Nozzle too big or worn;
• The product is too dense;
• The nozzle is partially clogged;
• There is no atomising air;
• The product is too dense;
• Gasket worn or needs adjustment;
• The nozzle is worn;
• Clean or replace it;
• Replace it with a larger-mesh filter
(with very dense products, remove
the filter);
• Check the suction pipe;
• Add the product;
• Check the suction pipe;
• Close the circulation tap;
• Replace it with a smaller one;
• Dilute the product, if possible;
• Clean or replace it;
• Check the flow regulator for the
atomising air;
• Dilute the product, if possible;
• Replace or adjust the gasket;
• Replace it;