17
the end of this procedure.
You can learn a maximum of 6 units between remote controls and 800/801sensors into the alarm.
SENSOR TEST
It is possible to test the garage sensors during the pre alarm time (30 seconds), like any other sensors.
Arm the alarm by remote control; the LED on the motorcycle will be constantly ON. Move the magnet
from the contact switch/create body movement within the range of the infra-red sensor; this will cause
the LED on the motorcycle to blink OFF for 1 second indicating that the protected areas have been
detected.
After the pre-alarm time (30 seconds), the activation of a sensor will cause the alarm to activate the
siren.
It is possible, by the “alarm trigger signalling” function, to verify that a garage sensor caused an alarm
condition.
NOTE: every time the magnetic contact or the infra-red sensor sends an alarm signal, the red LED on
the sensor lights for 2 seconds. The sensors have a battery saving function. After an alarm signal as been
transmitted to the alarm by a sensor, the sensor is inhibited for 30 seconds and it must not detect any
variations (keep still or move away from the protected area), otherwise this time will be extended and
the sensor will not emit any alarm signal until a least 30 seconds have past without detecting.
EXCLUSION OF THE INFRA-RED SENSOR (801V1D ONLY)
It is possible to exclude the infra-red sensor by the appropriate switch situated on the plastic body of the
sensor. Switching the sensor back on will cause the LED on the sensor to illuminate for 2 seconds.
TECHNICAL DATA
Power supply:...................................................................................................................battery 9V
Battery type: .............................................................................................. MN 1604 6LR61 9 Volts
Battery life:................................................................................................................... 6-12 month
Radio transmitter frequency: ......................................................................................... 433.9 MHz
*The optional Magnetic contact switch (800) and the Infra-red sensor (801) are under re-
development at the time of going to print, please refer to the instruction that are supplied with these
units for the latest information.