31
CoatingTest-Master
Technical data
Sensor FE NFe
How it works Magnetic induction Eddy current
Measuring range 0…1250 μm 0…1250 μm
Accuracy /
tolerance
0…850 μm /
± (3% +1 μm),
850…1250 μm / (±5%)
0…850 μm /
± (3% +1 μm),
850…1250 μm / (±5%)
Minimum bending
radius
1.5 mm 3 mm
Diameter of the
smallest measuring
surface
ø 7 mm ø 5 mm
Operating conditions
0°C…40°C, Max. humidity 20 … 90%rH,
no condensation, Max. working altitude
2000 m above sea level
Storage conditions -10°C…60°C, Max. humidity 80%rH
Power supply 2 x AAA
Dimensions (W x H x D) 50 x 110 x 23 mm
Weight 100 g
Technical revisions reserved. 18W03
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=coatemas