EasyManua.ls Logo

LAUMAS W100 - TARE OPERATIONS; Semi-Automatic Tare (Net;Gross)

LAUMAS W100
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 18 -
- setpoint = 0 and switching = : relay switching occurs for a weight higher than or equal
to 0, the relay will switch again for values below 0, taking hysteresis into account.
- setpoint = 0 and switching = : relay switching occurs for a weight lower than or equal
to 0, the relay will switch again for values above 0, taking hysteresis into account.
INPUTS
Default: input 1 =  input 2 =  input 3 = 
Possible operation modes:
-  (NET/GROSS): by closing this input for no more than one second, it’s making an
operation of SEMI-AUTOMATIC TARE and the display will show the net weight. To display the
gross weight again, hold the NET/GROSS input closed for 3 seconds.
- : by closing the input for no more than one second, the weight is set to zero (see section
WEIGHT ZERO-SETTING FOR SMALL VARIATIONS (SEMI-AUTOMATIC ZERO)).
- : keeping the input closed the maximum weight value reached remains on display. Opening
the input the current weight is displayed.
- : closing the input no operation is performed, the input status may however be read remotely
by way of the communication protocol.
- : closing the input for max one second the weight is transmitted over the serial
connection according to the fast continuous transmission protocol only once (only if  is
set in the item ).
- : when the input is closed the weight is displayed based on the set coefficient (see setting
of the units of measure and coefficient), otherwise the weight is displayed.
-
: when the input is closed the data are sent for printing if in the communication protocol
of either serial port the parameter  is set.
SEMI-AUTOMATIC TARE (NET/GROSS)
THE SEMI-AUTOMATIC TARE OPERATION IS LOST UPON INSTRUMENT POWER-
OFF.
To perform a net operation (SEMI-AUTOMATIC TARE), close the NET/GROSS input or press the
TARE key for less than 3 seconds. The instrument displays the net weight (just set to zero) and the
NET LED lights up. To display the gross weight again, keep the NET/GROSS input closed or press
TARE for 3 seconds.
This operation can be repeated many times by the operator to allow the loading of several products.

Table of Contents