Portable Plasma Torch Height Controller Manual (F1620)
13
collision halt signal to CNC during
torch work.
P12
0 1 1 P12 1 Switching motor contrary or positive
direction of rotating. Instead of
changing wiring, changing this
parameter can change the motor
direction of rotating.
P13
0 1 1 P13 1 Enable the proximity switch collision
check. When user set it as 1, the
proximity switch collision check is
allowed.
P14
1-50 1 50 P14 50 Brake speed adjust step and length.
When set it as 50, brake speed is
fastest.
P15
1-100 1 100 P15 100 Speed adjust step and length when
motor turn contrary. The bigger value
can make reversal transition speed
become more and more smaller.
P16
0.1-2 0.01 0.2 P16 0.2 UnitSecond(S). Arc voltage delay
time of setting.
P17
0-10 0.1 1 P17 1.0 UnitSecond(S). The lifting time of
starting up.
P18
0.1-1
0
0.1 2 P18 2.0 Unit Second(S).The time of
promoting the spear after torch have
accomplished
P19
0-9.9
9
0.01 0 P19 0 Unit Second(S).Torch lifting time
when arc start start to work.
P20
0-20 0.1 6 P20 6.0 Unit Second(S). The time of
descending rapidly during the dual
speed IHS.
Parameter explain particularly:
1. P00Recovering factory parameter. P00 can display 1. If user set it as 0 and
save this parameter, all kinds of parameter in our equipment will recover factory
parameter. After user exit the submenu, they can find that P00 display 1.
2. P01P02P03P04Setting manul lifting and auto lifting speed of torch. The
minimum speed is 0, the maximum speed is 50.
3. P05 The value of promoting arc voltage. During torch is cutting, if gun of