EasyManua.ls Logo

LEGRAND 0 489 35 User Manual

LEGRAND 0 489 35
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Cat. No(s): 0 489 35
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017
1/8
PIR+US ceiling mount sensors
(DALI)
CONTENTS Page
1. Use ......................................1
2. Technical characteristics .................1
3. Installation...............................2
4. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5. Connection ..............................3
6. Operation................................5
7. Settings..................................5
8. Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9. Care .....................................7
10. Standards...............................8
11. Troubleshooting ........................8
1. USE 2. TECHNICAL CHARACTERISTICS
DALI sensor Cat. No. 0 489 35 is a device which measures the daylight
level and detects presence of people using dual technology (passive
infrared and ultrasonic (PIR + US)).
It can be surface-mounted on a concrete ceiling using box
Cat. No. 0 488 75, or flush-mounted directly in a suspended ceiling using
claws or in a flush-mounting box Cat. No. 0 800 31.
It is suitable for indoor workspaces such as offices, meeting rooms,
classrooms, etc and it can be used on its own or in combination with
DALI power supply/wiring unit Cat No. 0 488 76.
This sensor can manage up to 2 groups of dimmer ECGs, “window”
and corridor” type (containing a maximum of 64 ECGs), for which it is
possible to configure an offset light level.
If it is used in combination with DALI power supply/wiring unit
Cat No. 0 488 76, it can manage up to three ECG groups (64 ECGs max).
These groups are made up as follows: 2 “window” and corridor groups
which can be used to dim the lighting, for which it is possible to set a
light level offset, and a display board” group which can only be switched
ON/OFF.
This sensor is fully configured using configuration tool Cat. No. 0 882 30/
BMSO4001 with which it is possible to:
- Distribute DALI ECG addresses
- Pair DALI ECGs with their sensor and their group (window, corridor or
display board)
- Define the light level offset between the “window group and the
corridor group
- Designate Master and Slave sensors
- Define the standby level when there is no detection
- Define the standby time
- Configure all the other sensor settings (for example, daylight setpoint,
time the lighting remains on after detection, choice of detection
technology, operating mode, etc.)
DALI sensor Cat. No. 0 489 35 is powered with 16 VDC by the DALI bus.
A DALI power supply Cat No. 0 035 15 or 0 035 13 can supply this
voltage to the DALI BUS with a maximum of 200 mA, and the DALI unit
Cat No. 0 488 76 also acts as the bus power supply.
Voltage: 12-20 V=
Consumption: 25 mA
Wiring:
- Power: 2 x 2.5 mm
2
DALI < 1.5 mm
2
Usage temperature: -5°C to +45°C
Storage temperature: -20°C to +70°C
Impact resistance: IK04
Penetration by solid and liquid matter: IP20
Weight: 115 g
DALI conguration red
LED
US sensor
PIR sensor
TEST button
Detection LED
IR transmission/
reception cell
Light level cell

Questions and Answers:

LEGRAND 0 489 35 Specifications

General IconGeneral
BrandLEGRAND
Model0 489 35
CategoryAccessories
LanguageEnglish

Summary

1. USE

2. TECHNICAL CHARACTERISTICS

3. INSTALLATION

5. CONNECTION

5.4 Wiring with several sensors, one control unit and a DALI unit

Wiring configuration for sensors, control unit, and DALI unit.

6. OPERATION

7. SETTINGS

7.1 Detection settings

Configuration of detection modes, sensitivity, and time delays.

7.2 Light level settings

Settings for daylight setpoint, calibration, and light regulation.

8. PERFORMANCE

11. TROUBLESHOOTING

Lighting stays on when no-one present

Solutions for persistent lighting when no presence is detected.

Lighting does not switch off in adequate daylight

Troubleshooting steps for lighting failing to turn off in sufficient daylight.

Lighting switches off when people present in darkness

Solutions for lighting switching off unexpectedly in low light conditions.

Related product manuals