Wattstopper
®
DLM Wireless PIR Corner Mount Occupancy Sensor with IPv6/
Bluetooth
®
Low Energy Technology
Quick Start Guide • Guide de démarrage rapide • Guía de inicio rápido
No: 27366 – 5/19 rev. 3a
Catalog Numbers • Numéros de Catalogue • Números de Catálogo: LMPX-600, LMPX-600-1, LMPX-600-4
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
SPECIFICATIONS
Power Supply .......................... Battery powered, CR123A Lithium Ion, 3 VDC
Connection to DLM Network ... Wireless via LMRC-611MCC room controllers
Lens Types
LMPX-600 .........................................................................Wide Angle
LMPX-600-1 .................................................................... Long Range
LMPX-600-4 ............................................................ Extra Wide Angle
Wireless Hardware
Radios: ................................................................ Two IEEE 802.15.4
Frequency: ............................................................................. 2.4Ghz
Antennas: ................................ IPv6 Mesh and Bluetooth low energy
Wireless Standards
Radio 1: ......................................................... IPv6 Mesh (6LoWPAN)
Range: .......................................................................up to 60 ft.
Radio 2: ............................................................ Bluetooth low energy
Range: .......................................................................up to 30 ft.
Wireless Encryption
AES-128 bit symmetric key, randomly generated per PAN
Shared via secured DTLS only
Environment ............................................................... For Indoor Use Only
Operating Temperature ...............................32° to 104°F (0° to 40°C)
Storage Temperature .................................23° to 140°F (-5° to 60°C)
Relative Humidity .....................................5 to 95% (non condensing)
Compliance/Regulatory
FCC, RoHS,
Bluetooth certified
UL and cUL listed (E101196)
Patent Pending
Once paired to an LMRC-611 wireless room
controller or LMBC-650 wireless bridge,
this unit is set for Plug n’ Go operation,
adjustment via the DLM Conguration App
is recommended to meet the local energy
code where installed.
The DLM Wireless corner mount sensor is a wireless
battery powered PIR occupancy sensor intended for
operation with wireless room controllers or bridges.
Once paired to a wireless room controller or bridge,
it detects and monitors the presence of motion to
determine if lights should be on or off.
COVERAGE PATTERNS
Coverages shown are maximum and represent half-step walking
motion.
Side view
8’
To
p view
60’
07 12’ 25’ 60’
100°
LMPX-600, wide angle lens
8ft
0
8ft
8ft
16ft
16ft
0
6’ 10ft 27ft 60ft
Top View
Side View
16ft
LMPX-600-1, long range lens
8ft
0
8ft
8ft
16ft
16ft
0
6’ 10ft 27ft 60ft
Top View
Side View
16ft
0 10ft 20ft 30ft 40ft 45ft
8ft
Side View
0
10ft
10ft
20ft
20ft
Top View:
LMPX-600-4, extra wide angle lens
Question and Answer IconNeed help?

Do you have a question about the LEGRAND Wattstopper Series and is the answer not in the manual?

LEGRAND Wattstopper Series Specifications

General IconGeneral
BrandLEGRAND
ModelWattstopper Series
CategoryAccessories
LanguageEnglish

Summary

SPECIFICATIONS

Key Specifications

Details power supply, connectivity, wireless hardware, environment, and compliance for the sensor.

COVERAGE PATTERNS

Lens Coverage Details

Illustrates detection ranges for wide, long, and extra wide angle lenses.

SENSOR PLACEMENT AND MOUNTING

Ceiling Mount Installation

Instructions for mounting the sensor on a ceiling.

Threaded Rod Mount Installation

Instructions for mounting the sensor on a threaded rod.

Ball Mount to Wall Installation

Instructions for mounting the sensor to a wall using the ball mount.

BALL MOUNT INSTALLATION

Ball Mount to J-Box

Procedure for mounting the sensor to a J-box.

Ball Mount to Ceiling

Procedure for mounting the sensor on a drop ceiling.

WIRELESS ROOM CONNECTION

System Components and Distances

Identifies devices and specifies connection distance recommendations.

DEVICE PAIRING

Recommended Pairing Methods

Outlines preferred methods for pairing devices in different network setups.

Push-to-Pair Procedures

Step-by-step guides for pairing using Push-to-Pair mode.

ADVANCED DEVICE MANAGEMENT

Pairing to Existing Network

Procedure for adding a device to an already set up network.

DLM Config App Usage

Details on using the mobile app for pairing and adjustment.

Resetting the LMPX-600

Instructions on how to reset the sensor to default settings.

REGULATORY AND WARRANTY INFORMATION

FCC Regulatory Statements

Compliance information regarding FCC rules and RF exposure.

Warranty Information

Details the product's five-year warranty coverage.

Related product manuals