Wattstopper
®
Ultrasonic Low Voltage Occupancy Sensor with Manual On Feature (v3)
Détecteur de présence à ultrasons basse tension avec marche en mode manuel (v3)
Sensor de ocupación ultrasónico de bajo voltaje con función de encendido manual (v3)
Installation Instructions • Instructions d’Installation • Instrucciones de Instalación
No: 24254 – 10/16 rev. 1
Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: UT-305-1, UT-305-2, UT-305-3
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
SPECIFICATIONS
Voltage ................................18-28VDC/VAC, half wave rectified AC
Current Consumption ...............................................................25mA
Power Supply ...........................................Wattstopper Power Packs
Operating Temperature .............................32° to 131°F (0° to 55°C)
Time Delay Adjustment ............................30 seconds to 30 minutes
Walk-Through Mode .......... 3 minutes if no activity after 30 sec.
Test Mode .................................... 5 sec. upon DIP switch reset
Ultrasonic Coverage
Model UT-305-1 ..................................................... up to 500 ft
2
Model UT-305-2 ................................................... up to 1000 ft
2
Model UT-305-3 ................................................... up to 2000 ft
2
Sensitivity Adjustment ............. Minimum to Maximum (trimpot)
Frequency .......................................................................40kHz
UL & CUL Listed for use with Wattstopper Power Packs
U.S. Patents: 7,277,012
DESCRIPTION AND OPERATION
The Wattstopper UT-305 sensors turn lighting systems on and off
based on occupancy.
The UT-305 can be configured to turn lighting on, and hold it on as
long as it detects cccupancy. After no movement is detected for a user
specified time (5 to 30 minutes) the lights are switched off. A “walk-
through” mode can turn lights off after only 3 minutes, if no activity is
detected after 30 seconds of an occupancy detection.
The UT-305 operates on 24V supplied by Wattstopper Power Packs.
The sensors can operate on 24VDC, 24VAC, or half wave rectified AC.
COVERAGE PATTERN
The UT-305 is available in 3 models. Each model has a different size
coverage pattern. The coverage shown represents walking motion at a
mounting height of 8 to 10 feet. For building spaces with lower levels of
activity or with obstacles and barriers, coverage size may decrease.
0'
5'
12'
16'
23'
0'
5'
16'23'45' 12'
12'
16'
23'
12' 16' 23' 45'
UT-300/305-3
UT-300/305-2
UT-300/305-1
UT-300/305-3
HALLWAY
APPLICATION
Drawings not to scale.
PLACEMENT GUIDELINES
Depending upon obstacles such as furniture or partitions, the area
of coverage may be less or more than the sensing distances shown
in the coverage pattern. This must be considered when planning the
number of sensors and their placement. It is also recommended to
place the sensor 4 to 6 feet away from air supply ducts.
Mount the sensor to the ceiling. The UT-305 is designed for a
ceiling height of about 8-10 feet. Mounting above or below this range
will significantly affect the coverage patterns. As a general rule, each
occupant should be able to clearly view the sensor.
Open Office Area Coverage: To get complete coverage in an open
office area, install multiple sensors so that there is approximately
20% overlap with each adjacent sensor’s ultrasonic coverage area.
2QH87
&RYHUDJH$UHD

8OWUDVRQLF
2YHUODS

Other manuals for LEGRAND Wattstopper UT-305-2

Questions and Answers

  • L
    Lorraine GregoryAug 10, 2025
    What to do if LEGRAND Wattstopper UT-305-2 lights do not turn on with occupancy and the LED doesn't flash?
    • T
      thomasamandaAug 10, 2025
      If the LEGRAND Accessories lights do not turn on with occupancy, and the LED does not flash, you can try the following: * Ensure the circuit breaker is turned back on. * Increase the Ultrasonic Sensitivity setting. * Check all sensor and power pack wire connections. If 24V is present, replace the sensor. If 24V is not present, check that high voltage is present to the power pack. If high voltage is present, replace the power pack.
  • G
    Gregory MosesAug 25, 2025
    Why are my LEGRAND Wattstopper UT-305-2 lights not turning off automatically?
    • L
      Louis SheppardAug 26, 2025
      If the LEGRAND Accessories lights do not turn off automatically, it could be due to sensor activations from outside the controlled area or interference. To resolve this: * Check all sensor wire connections. * Disconnect the power pack’s blue wire. If the lights do not turn off, replace the power pack and reconnect the blue wire. If the lights turn off, the problem may be in the sensor. * Reconnect the blue wire. * Turn the sensitivity and time delay to the minimum and allow the sensor to time out. If the lights turn off, the sensor is working properly.

LEGRAND Wattstopper UT-305-2 Specifications

General IconGeneral
Sensor TypeUltrasonic
Detection TechnologyUltrasonic
MountingCeiling
Operating Temperature0°C to 40°C (32°F to 104°F)
Time DelayAdjustable from 30 seconds to 30 minutes
Ambient Temperature Range0°C to 40°C (32°F to 104°F)
Dimensions4.5" diameter x 1.5" depth
TypeUltrasonic Occupancy Sensor
Mounting Height8 to 12 ft
Humidity Range20% to 90% RH, non-condensing