Technical data sheet: S000074405EN-2 Updated: 10/02/2016 Created: 18/01/2013
Catalogue Number(s): 0 488 04
PIR switch sensor
1. USE
This device allows a light source to be controlled automatically through
the detection of movement in the surveillance zone.
It is equipped with a "presence" output for ventilation or lighting
control. This output is separate from the level of light.
Motion sensor with 360° detection angle.
Detection type: infrared (PIR)
Mounting type: ceiling
2. TECHNICAL CHARACTERISTICS
Voltage: 100 - 240 V~
Frequency: 50/60 Hz
No-load power consumption: 0.8 W
Output via normally open contact connected to the phase
Wiring: 2 x 2.5 mm
2
Drilling diameter: 85 mm without flush-mounting box
85 mm with flush-mounting box
Weight: 114 g
Impact resistance: IK04
Penetration by solid and liquid matter: IP20 (unmounted)
IP41 (mounted)
Usage temperature: - 5°C to + 45°C
Storage temperature: - 20°C to + 70°C
2.TECHNICAL CHARACTERISTICS (continued)
Cover removed
CONTENTS Page
1. Use.....................................1
2. Technical characteristics . . . . . . . . . . . . . . . .1
3. Dimensions.............................2
4. Connection .............................2
5. Installation .............................4
6. Removal ................................4
7. Operation ..............................5
8. Settings ................................6
9. Performance . . . . . . . . . . . . . . . . . . ........7
10. Care . . . . . . . . . . . . . . . . . . . . . .............8
11. Standards and approvals ................8
12. Troubleshooting ........................8
1 - Halogen bulb
2 - ELV halogen bulb with separate electronic ballast
3 - ELV halogen bulb with separate ferromagnetic ballast
4 - Fluorescent tube with separate ferromagnetic ballast
5 - ELV fluorescent tube with separate electronic ballast
6 - Compact fluorescent bulb with built-in electronic ballast
7 - Compact fluorescent bulb with separate ferromagnetic ballast
8 - Compact fluorescent bulb with separate electronic ballast
9 - LED bulb
10 - Contactor
11 - Motor
230 V~ 2000 W
8.5 A
1000 VA
4.3 A
10x(2x36 W)
4.3 A
500 VA
2.1 A
1000 VA
4.3 A
500 VA
2.1 A I max. ≤ 2A
110 V~ 1000 W 500 VA 5x(2x36 W) 250 VA 500 VA 250 VA
1 2 3 4 5 6 7 8 9
LEARN button
LEARN LED
Green
programming
indicator
IR transmission LED
(for configuration
tool)
Sensor/PIR
sensor
IR receiver LED
(for configuration
tool or remote
control)
Protective cover
Green
detection
indicator
Light level cell
230 V~ 2000 W
8.5 A
I max. ≤ 2A
110 V~ 1000 W
U ≤ 30 V=
2 A max.

Questions and Answers

  • B
    Brandon RasmussenAug 3, 2025
    How to fix LEGRAND 0 488 04 lighting that stays on?
    • A
      Amy JordanAug 3, 2025
      If the LEGRAND Accessories lighting stays on even when no one is around, it could be due to interference from things like draughts, vibrations, or radiators which may cause nuisance tripping. Try reducing the sensitivity level. If the problem continues, use the configuration tool to go into the Detection system parameters, select Maintain, and then choose PIR and US. If the issue persists, consider moving the sensor away from any potential sources of interference.
  • R
    Roger PetersAug 14, 2025
    Why won't my LEGRAND 0 488 04 Accessories light turn off during the day?
    • A
      Alexandra JenningsAug 14, 2025
      If your LEGRAND Accessories lighting doesn't switch off during the day when there's enough natural light, the regulation function might not be active; try activating it. The light level threshold could also be set too high, so try reducing it. Ensure that the sensor is correctly positioned in relation to the window. Also, consider decreasing the power of the luminaires.
  • M
    melvin77Aug 25, 2025
    What to do if LEGRAND 0 488 04 Accessories lighting switches off with people present?
    • H
      hortontimothyAug 25, 2025
      If your LEGRAND Accessories lighting switches off even when people are present and there isn't enough natural light, the time delay might be too short. Try increasing the time delay; 10 to 15 minutes is recommended for work areas. Also, the detection sensitivity could be too low, so increasing the sensitivity may help. Another cause might be that the light level threshold is too low; in this case, try increasing the threshold or move the sensor closer to the work area.

Summary

Technical Characteristics of PIR Sensor

Connection and Wiring

Wiring with Auxiliary Control

Details wiring for auxiliary control connections with diagrams and parameters.

Single Load Parallel Wiring

Illustrates parallel wiring for a single load using multiple sensors.

Multiple Load Parallel Wiring

Shows parallel wiring for multiple loads with several sensors connected.

Installation of PIR Sensor

Sensor Positioning Guidelines

Provides guidance on optimal sensor placement for effective detection.

Operation Modes and Synchronization

Settings and Configuration

Performance Data

Troubleshooting Common Issues

LEGRAND 0 488 04 Specifications