Group 7 Data/Programming Page 162
Release R2.0 LEIBINGER JET3
7.4.4 Special functions and tools
Under the tab <Special Functions/Tools> the following functions are available:
Ignore error messages and warnings
The function constant bleeding is only activated or functional under the
following device conditions:
Ink suction is turned on
Nozzle is closed
Head cover has been detached
By pressing the button <Constant Bleed> (1) the constant bleeding is started. During
the process the message „Constant Bleed“ (2) is displayed. The bleeding can be
canceled any time by pressing on the button <Stop> (3). During this process the
visco pump is activated for 3 sec. every minute to ensure a purging of the pump.
With the button <Add Solv> (4) you can add only solvent. This function provides
specially filling operations to bleed e.g. the solvent tube or to set the viscosity of the
ink faster to a lower value.
By adding solvent the ink can be diluted too strong. Therefore this
function should only be carried out by qualified personnel.