Group 8 Job editor Page 275
Release R2.0 LEIBINGER JET3
The height of the printout of the selected bar code type is defined with the <Bar
height> (6) setting. The height is measured in dots. The JET3 printer is able to print
up to 32 dots in vertical direction. Therefore <Bar height> can be set to a value
between 0 and 32.
Bar code type code 39 with
different <Bar height>
settings.
The height of the plain text
depends on the selected font.
In this example it is a 7x5
font.
Pushing the <Default Settings> button (8) will open the <Barcode Format Default
Settings> dialog box (10). In this dialog box the default settings for the 3 preset
<Styles> can be adjusted. There is a tab for each <Style> (11-13). All changes
confirmed with the <OK> button will be applied to the <Style> settings in the
<Barcode format> dialog box. The <Cancel> button will close the dialog box
without changes.
For 2-D bar codes like the ECC200 code the <Barcode format> dialog box (14)
offers different options. For 2-D bar codes there are 3 <Styles> available (15). With
the styles the number of printed dots which are used per 2-D code square is defined.
<1x1> <Style>: one square of the 2-D code is printed with 1 dot (16).
<2x2> <Style>: one square of the 2-D code is printed with 4 dots (17).
<3x3> <Style>: one square of the 2-D code is printed with 9 dots (18)