EasyManua.ls Logo

Leibinger Jet 3 - Grounding Regulations for Print Head Cleaning

Leibinger Jet 3
378 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group 10 Equipping/Maintenance Page 347
Release R2.0 LEIBINGER JET3
Safety- and disposal instructions
1.
Please only replace with the same battery or with a comparable
type of battery according to the recommendation of the
manufacturer!
Danger of
explosion
2.
Pay attention to the correct polarity (+/-)!
3.
Do not throw battery into fire!
4.
Do not load battery again!
5.
Do not use conductive tools to change the battery!
Danger of
short circuit
6.
Do not open battery!
7.
Do not dispose battery in the household garbage!
Figure 174
Replacement of the battery
1 Battery, lithium, 3.2 VDC (54-003 032 KA)
2 Safety indication
10.2.4.2 Pressure regulator valve ( ext. print head ventilation (opt. equip.))
Resulting condensate must be emptied at regular intervals and the cartridge cleaned.