Group 5 Transport/Start up Page 46
Release R2.0 LEIBINGER JET3
5.4.2 Fill reservoir tank
To avoid damages of the device during the transportation the reservoir tanks should
be evacuated and have to be filled before the initial operation.
Danger of explosion!
Before filling the device with the consumables, measures for the
electrostatic discharge have to be made!
The operator can carry out a discharge either by the direct touching of
the LJ3-cabinet or by standing with the appropriate ESD-shoes on an
grounded surface!
Dangerous material in the machine!
Danger of serious damage through burns, skin irriation and
poisoning!
Protective equipment is necessary! Read the safety data sheets and
the personal protective equipment rules and regulations!
The reservoir tanks for ink and solvent are installed beneath the cover flap of the refill
unit (see illustration below).
The two reservoir tanks are monitored by level sensors. They are always
unpressurized and can be opened in every device condition.
The reservoir tanks and the sealing cap are color-coded and labelled to avoid any
mistakes in filling. Additionally the sealing caps are marked with the ink-no. or
solvent-no. which are admissible for the device.
For correct handling the LEIBINGER re-filling system allows an odor- and splash free
refilling of the consumables.