Group 5 Transport/Start up Page 52
Release R2.0 LEIBINGER JET3
Proceeding
Turn the adjusting knob (2) of the pressure regulator valve (1), until the necessary
pressure of 1.4 bar is reached.
Figure 12
Setting the pressure regulator
Setting the pressure regulator
(external head ventilation)
1 Pressure regulator valve
3 Indicating label
2 Adjusting knob
4 Manometer
INFORMATION
Supplementary information for the assembly and function can be found
in the chapter External print head ventilation (assembly and function)!
ATTENTION
Make sure that there is a permanent compressed air supply!
The printer doesn’t monitor the permanent compressed air supply!
There will be no warning in case the permanent compressed air
supply fails!
Operation is only permissible with dry, oil-free and filtered
compressed air (Filtering 8 m) The use of otherwise prepared
compressed air can lead to damage and malfunctions!
3
2
Set point: 1.4 bar