Leica M205 FCA - User Manual

Leica M205 FCA
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Leica M165 FC
Leica M205 FA / M205 FCA
User Manual

Table of Contents

Questions and Answers

  • D
    Deborah FordAug 8, 2025
    What to do if the Leica M205 FCA Microscope target system receives too little light?
    • T
      Taylor RobinsonAug 8, 2025
      If your Leica Microscope's target system isn't receiving enough light, or any at all, here's what you can check: * Ensure the shutter is open and the intensity switch isn't at its leftmost limit. If it is, open the shutter or rotate the intensity switch to the right. * Verify the light guide is correctly inserted into the light guide output. * Inspect the light guide for any damage. If damaged or defective, it should be repaired or replaced.
  • J
    Jason WintersAug 19, 2025
    Why is the Leica M205 FCA power indicator not illuminated?
    • S
      Sherry OlsonAug 19, 2025
      If the power indicator on your Leica Microscope isn't lighting up and the instrument isn't functioning after being switched on, it could be due to a few reasons: 1. Check that the power supply voltage is present and that the connecting cable is correctly plugged in and not defective. 2. Inspect the fuses in the instrument. If they are defective, replace them, ensuring you use the permitted replacement type only.
  • A
    Anna GomezAug 28, 2025
    What to do if Leica Microscope power switch is on but no function?
    • T
      Thomas CohenAug 29, 2025
      If the power switch on your Leica Microscope is illuminated but the instrument isn't functioning, the issue might be: * The housing cover may be loose or removed. Make sure to securely attach the housing cover. * The lamp might be worn out and needs replacing.

Summary

General Instructions

Safety concept

Read the "Safety concept" booklet for handling and care information.

Servicing

Repairs must be performed by trained technicians using original parts.

Important Safety Notes

Safety Instructions

Intended use

Refer to the "Safety Concept" booklet for intended use guidelines.

Safety Instructions (Continued)

Light sources: Safety regulations

Protective measures required for UV radiation from light sources.

Lamp housing

Safety precautions for opening the lamp housing and covering air ducts.

Assembly

Objective Nosepiece - Adjusting Parfocality

Procedure to adjust parfocality between objectives for seamless focus.

Transmitted-light Base Leica TL BFDF: Before First Use

Leica IsoPro Motorized Mechanical Stage: Assembly

Leica LED5000 MCI

Leica EL6000 - Safety Notes

Leica EL6000 - Preparations

Inserting the lamp

Steps to disconnect power, remove cover, and insert the lamp.

The Correct Interpupillary Distance

Using the Eyepieces

Focusing

Parfocality: More Comfort and Convenience for Your Work

Parfocality

Explanation of parfocality and how to maintain it across magnifications.

Health Notes

Potential sources of infection

Risk of infection transmission via eyepieces; use individual eyepieces.

The Objective Nosepiece

Parfocal work

Maintaining parfocality when changing objectives.

Leica TL ST Transmitted-light Base: Operation

Leica TL BFDF Transmitted-light Base: Operation

Leica TL RC; Leica TL RCI: Operation

Leica TL RCI: Methods in Transmitted Light

Using Filters

Leica IsoPro (Non-motorized): Controls

Leica EL6000 - About the Instrument

Leica EL6000 - Operation

Leica EL6000 - Troubleshooting

Cleaning and Maintenance

Replacing the instrument fuse

Steps for disconnecting power and replacing the instrument fuse.

Fluorescence

Filter Changer

Description of filter sets, barrier and excitation filters, and transponders.

Double Iris Aperture

Commissioning the Fluorescence System

For observation with fluorescence light

Always position protection screen correctly to protect the observer.

Specifications

Leica EL6000 - Specifications

Electrical safety, power input, and protective functions for the EL6000.

Leica M205 FCA Specifications

General IconGeneral
TypeStereo Microscope
Working Distance18.9 mm - 297 mm (depending on objective)
Aperture diaphragmYes
Field diaphragmYes
Magnification7.8x - 160x (with 10x eyepieces and 1x objective)
ObjectivePlanApo 1.0x, PlanApo 2.0x