Leica DM750 M User Manual

Leica DM750 M
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Leica DM750 M
User Manual

Other manuals for Leica DM750 M

Question and Answer IconNeed help?

Do you have a question about the Leica DM750 M and is the answer not in the manual?

Leica DM750 M Specifications

General IconGeneral
CategoryMicroscope
IlluminationLED
NosepieceQuadruple nosepiece
Objective Lenses4x, 10x, 40x
StageMechanical stage
FocusCoaxial coarse and fine focus
Eyepieces10x
CondenserAbbe Condenser
Power SupplyExternal power supply
Magnification Range40x to 1000x

Summary

Manufacturer Information Leica

Safety Regulations Leica DM750 M

Safety Concept for Leica Microscopes

Explains user manuals and safety instructions for safe operation of Leica DM microscopy series.

Symbols Used in this Instruction Manual

Details warning symbols, danger symbols, and important information indicators used in the manual.

Important Notes for Instrument Use

Provides general precautions, user manual details, and third-party supplier guidelines for safe use.

Instructions on Use and Non-intended Use

Covers proper usage, place of use, and non-intended use to ensure safety and prevent damage.

Health Risks and Dangers of Use

Discusses potential health risks and operational dangers, including eye strain and electrical hazards.

Information for the Person Responsible

Outlines responsibilities for safe operation, qualified personnel, and proper maintenance of the instrument.

Care Instructions for Leica DM750 M

Provides general instructions and methods for cleaning coated parts, plastic parts, and glass surfaces.

Accessories, Maintenance and Repair

Details approved accessories, maintenance recommendations, and guidelines for repairs and service work.

Electrical Data and Ambient Conditions

Lists electrical specifications, fuse replacement, and environmental operating conditions for the microscope.

Assembling the Leica DM750 M

Assembling the Incident Light Axis

Step-by-step guide on how to attach the incident light axis to the microscope's tripod mount.

Assembling the Viewing Tubes

Instructions for attaching different types of viewing tubes to the microscope stand using setscrews.

Leica EZ Viewing Tube with Integrated Eyepieces

Specific instructions for installing and rotating the Leica EZ viewing tube with integrated eyepieces.

Leica Standard Tube with Separate Eyepieces

Instructions for inserting and securing eyepieces into the standard viewing tube.

Eyecups Adjustment for Viewing

Guidance on using eyeguards for eyeglass wearers and for blocking ambient light.

Installing Objectives on Leica DM750 M

Provides instructions on how to properly screw objectives into the objective nosepiece using the knurled ring.

Conversion to Incident Light Polarization

Steps to convert the microscope for incident light polarization by inserting polarizer and analyzer.

Use of the Leica DM750 M Microscope

Switching on the Microscope

Details the process of connecting and switching on the microscope's illumination and adjusting brightness.

Modifying the Aperture Diaphragm

Explains how to open or close the aperture diaphragm to adjust resolution and depth of field.

Illumination Scenarios and Modes

Describes how to adjust incident light illumination modes and switch between bright-field and oblique illumination.

Automatic Shutoff of Illumination

Explains the automatic shutoff feature and how to activate or deactivate delayed shutoff for the illumination.

Using Specimen Holders

Instructions on how to insert and position specimens using different types of specimen holders.

Conversion and Use with Transmitted Light

Optional Koehler Illumination Setup

Introduces the two types of condensers available for transmitted illumination.

Installing the Condenser

Step-by-step guide on how to install the condenser into the microscope's open holder.

Complete Condenser Centering Procedure

Detailed procedure for precisely centering the condenser for optimal illumination.

Using the Condenser Iris Diaphragm

Explains how to adjust the iris diaphragm of the condenser to match the objective's numerical aperture.

Preparation for Viewing a Specimen Slide

Instructions on positioning the specimen slide correctly under the objective using slide grips.

Focusing the Microscope Specimen

Describes the process of bringing the specimen into focus using coarse and fine focusing knobs.

Viewing Tube Adjustment for Users

Guides on adjusting the eyetubes for interpupillary distance and setting focusing eyepieces.

Koehler Configuration Steps

Steps to adapt and center the Koehler field diaphragm for optimal illumination.

Care of the Microscope

General Maintenance and Cleaning

Provides general handling instructions, cleaning methods for optical surfaces, and dust protection.