6. Measurement
6.1 Measuring principle
The load profiles are recorded in datasets at parameterized intervals.
The measuring circuit comprises a Sigma Delta ADC for each measuring channel which enables
simultaneous capturing of measured values at a sample rate of 4800 Hz. The Sigma Delta method
effectively suppresses high-frequency interference on the channels.
The microprocessor reads in the sampled values and calculates the active power and active energy
over adjustable intervals (standard value = 5 min). The datasets are backed up in Flash memories.
The supply voltage can be selected between 24 and 110V as per EN 50155. Optionally a communication
unit (modem) can be supplied with voltage of 12 V via the EM4TII+.
6.2 Formula: generation of measured values
Measured values are generated at one second intervals from 4800 sample values:
Effective voltage value