Lists callouts and descriptions for the LNL-1300 board components and mounting holes.
Details hardware requirements and notes for the LNL-1300 module, including power and input voltage.
Diagrams and descriptions for TTL, RS-485, and F/2F reader connections.
Wiring diagram for controlling DC door strikes with contact protection circuits.
Identifies components for RS-485 communication wiring, including terminator jumper and controller connection.
Explains DIP switch settings for device address, communication baud rate, and encryption.
Tables detailing DIP switch settings for baud rate and bus encryption.
Description of LED indicators and summary of electrical/mechanical specifications.
States FCC compliance rules and conditions for the device.
Defines limitations on use, liability, and warnings for professional installation.
The LNL-1300 Series 3 Single Reader Interface Module is designed to bridge various reader technologies and door hardware with a host control system, providing a comprehensive solution for access control applications. It supports multiple reader types, including TTL (D1/D0, Clock/Data), F/2F, and 2-wire RS-485 devices, making it versatile for different security setups.
The LNL-1300 acts as an intermediary between readers and door hardware and a Lenel intelligent controller (e.g., LNL-3300) via a 2-wire RS-485 interface. It translates reader data and manages door hardware, including strike control and alarm signaling. The module features two Form-C contact relay outputs for strike control or alarm signaling, and two inputs for monitoring door contacts and request-to-exit (REX) push buttons. These inputs can be configured as either unsupervised or supervised, with end-of-line (EOL) resistors required for supervised configurations.
The device also provides tri-stated LED control and buzzer control for reader feedback. Communication to the controller is half-duplex, multi-drop, and supports a total cable length of up to 4000 feet (1219 m) using shielded 24 AWG cable with a characteristic impedance of 120 ohms. The last device on the communication line requires a terminator jumper (J1) to be installed.
The LNL-1300 is designed for installation by experienced security professionals. It is crucial to follow the provided wiring diagrams and specifications to ensure proper operation and system reliability.