EasyManuals Logo

Lennox 13ACC Series User Manual

Lennox 13ACC Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Page 11
Table 5
Normal Operating Pressures In psig (liquid and suction +/− 2 psig)*
Unit /
Mt i
Out. Coil
Entering
−024 −030 −036 −037 −042 −047 −048 −060
Metering
Device
E
n
t
er
i
ng
Air Temp.
5F
(
5C
)
LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC.
65 (18.3) 145 79 143 73 148 77
157 78
144 77 146 73
151 69
171 75
70 (21) 158 79 154 74 160 78
170 79
156 78 158 74
163 71
184 77
75 (23.9) 170 80 167 74 175 79
184 80
170 79 171 74
177 72
197 78
80 (27) 184 81 181 75 190 79 198 81 185 79 185 75 191 73 211 79
85 (29.4) 198 82 195 75 205 80
213 81
199 80 200 76
206 74
226 79
13ACC
TXV
90 (32) 213 82 210 76 221 81 229 82 215 80 215 73 221 75 242 80
TXV
95 (35.0) 229 83 227 76 237 82
242 82
231 81 231 77
237 796
257 80
100 (38) 245 84 242 77 253 82 263 83 249 81 248 77 254 76 276 81
105 (40.6) 262 84 259 7 272 82
279 84
266 81 265 78
271 77
294 82
110 (43) 279 85 277 79 291 83
296 84
284 81 284 79
289 78
312 83
115 (45) 297 86 296 80 310 83
316 85
303 82 303 80
289 78
334 83
65 (18.3) 147 69 140 61 149 68
150 66
147 68 139 59
148 59
169 68
70 (21) 160 73 152 64 162 71
165 70
159 71 155 62
163 63
183 71
75 (23.9) 173 76 166 68 176 74
180 74
173 74 166 64
177 66
198 74
80 (27) 187 78 180 71 190 76 195 77 186 75 177 66 191 68 213 76
85 (29.4) 201 80 194 73 204 78
210 79
200 77 190 67
206 71
228 78
13ACC
RFC
90 (32) 216 82 209 75 219 80 226 81 214 79 201 68 223 73 245 80
RFC
95 (35.0) 231 83 224 76 236 81
242 82
231 80 220 70
238 75
261 81
100 (38) 246 85 241 77 252 82 260 84 247 81 238 71 257 76 279 82
105 (40.6) 262 86 257 78 270 84
279 85
264 83 256 72
274 77
297 83
110 (43) 279 86 276 81 288 85
297 86
281 84 271 73
292 79
316 85
115 (45) 298 87 294 82 307 86
313 87
300 85 290 74
309 80
336 86
*These are typical pressures only. Indoor evaporator match up, indoor air quality, and evaporator load will cause the pressures to vary.