07/11 506294−01
*2P0711* *P506294-01*
Page 1
E2011 Lennox Industries Inc.
Dallas, Texas, USA
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
CAUTION
Physical contact with metal edges and corners while
applying excessive force or rapid motion can result in
personal injury. Be aware of, and use caution when
working near these areas during installation or while
servicing this equipment.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
INSTALLATION
INSTRUCTIONS
Elite
®
Series CBX27UH
Units
MULTI−POSITION AIR HANDLERS
506294−01
07/11
Supersedes 05/11
Table of Contents
CBX27UH Up−flow/Down−flow Unit Dimensions 2. . .
CBX27UH Horizontal LH/RH Unit Dimensions 3. . . .
General Information 4. . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List 4. . . . . . . . . . . . . . . . . . . . . .
Requirements 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Unit 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brazing Connections 6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Condensate Drain 7. . . . . . . . . . . . . . . . .
Inspecting and Replacing Filters 8. . . . . . . . . . . . . . . . .
Sealing the Unit 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measuring Static Pressure 9. . . . . . . . . . . . . . . . . . . . .
Adjusting the Blower Speed 9. . . . . . . . . . . . . . . . . . . .
Making Electrical Connections 11. . . . . . . . . . . . . . . . . .
Repairing or Replacing Cabinet Insulation 15. . . . . . . . .
TOP CAP SHIPPING
BRACKET (REPLACE
SCREWS IN TOP CAP
AFTER REMOVAL)
HORIZONTAL DRAIN PAN (SEE PAGES 4
AND 6)
BLOWER HOUSING
SUPPORT PAD
IMPORTANT INFORMATION TO INSTALLER
CHECK FOR AND REMOVE THE FOLLOWING ITEMS BEFORE OPERATING UNIT.
REFRIGERANT LINE PLUGS
(SEE PAGE 6)
DRIP SHIELD FOR −060 UNITS ONLY
HORIZONTAL APPLICATIONS (SEE
PAGE 5).
D
D
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBX27UH and is the answer not in the manual?

Summary

Important Information for Installers

Unit Dimensions and Specifications

Up-flow and Down-flow Unit Dimensions

Detailed dimensions for CBX27UH units in up-flow and down-flow configurations.

Horizontal Unit Dimensions

Dimensions for CBX27UH units in horizontal left- and right-hand discharge configurations.

General Installation and Requirements

General Information and Shipping

Overview of the air handler, safety guidelines, and shipping/packing list details.

Installation Requirements and Standards

Covers unit matching, code compliance (NFPA), and clearance requirements.

Unit Configuration and Installation

Up-flow Installation

Procedures for configuring and installing the unit for up-flow operations.

Horizontal Discharge Installation

Steps for configuring and installing for horizontal right-hand and left-hand discharge.

Down-flow Installation

Instructions for setting up the unit for down-flow airflow configuration.

Refrigerant System Connections

Brazing Connections Procedure

Guidelines and safety precautions for brazing refrigerant lines.

Condensate Management

Installing the Condensate Drain

Instructions for connecting the main and overflow condensate drains.

Airflow and Filtration

Inspecting and Replacing Filters

Procedure for checking, cleaning, or replacing the air filter.

Sealing the Unit

Ensuring airtight seals between the unit and plenums for efficiency.

Performance Measurement and Adjustment

Measuring Static Pressure

Steps to measure static pressure for optimal airflow performance.

Adjusting Blower Speed

Guide to selecting and changing blower motor speed taps for correct CFM.

Electrical Connections

Wiring Procedures and Diagrams

Instructions for making line voltage and low voltage wiring connections.

Cabinet Insulation Maintenance

Repairing or Replacing Cabinet Insulation

Procedures for repairing damaged insulation and safety warnings.

Summary

Important Information for Installers

Unit Dimensions and Specifications

Up-flow and Down-flow Unit Dimensions

Detailed dimensions for CBX27UH units in up-flow and down-flow configurations.

Horizontal Unit Dimensions

Dimensions for CBX27UH units in horizontal left- and right-hand discharge configurations.

General Installation and Requirements

General Information and Shipping

Overview of the air handler, safety guidelines, and shipping/packing list details.

Installation Requirements and Standards

Covers unit matching, code compliance (NFPA), and clearance requirements.

Unit Configuration and Installation

Up-flow Installation

Procedures for configuring and installing the unit for up-flow operations.

Horizontal Discharge Installation

Steps for configuring and installing for horizontal right-hand and left-hand discharge.

Down-flow Installation

Instructions for setting up the unit for down-flow airflow configuration.

Refrigerant System Connections

Brazing Connections Procedure

Guidelines and safety precautions for brazing refrigerant lines.

Condensate Management

Installing the Condensate Drain

Instructions for connecting the main and overflow condensate drains.

Airflow and Filtration

Inspecting and Replacing Filters

Procedure for checking, cleaning, or replacing the air filter.

Sealing the Unit

Ensuring airtight seals between the unit and plenums for efficiency.

Performance Measurement and Adjustment

Measuring Static Pressure

Steps to measure static pressure for optimal airflow performance.

Adjusting Blower Speed

Guide to selecting and changing blower motor speed taps for correct CFM.

Electrical Connections

Wiring Procedures and Diagrams

Instructions for making line voltage and low voltage wiring connections.

Cabinet Insulation Maintenance

Repairing or Replacing Cabinet Insulation

Procedures for repairing damaged insulation and safety warnings.

Overview

The Lennox Elite® Series CBX27UH is a multi-position air handler designed for indoor use, capable of operating in up-flow, down-flow, and horizontal (left-hand or right-hand discharge) configurations. It is intended for installation with an optional field-installed electric heat section and a matching HFC-410A outdoor unit.

Function Description

The CBX27UH air handler is a key component of a complete heating and air conditioning system. Its primary function is to circulate conditioned air throughout a building, working in conjunction with an outdoor unit (condensing unit or heat pump) and an optional electric heat section. The unit draws return air from the conditioned space, passes it over an evaporator coil (for cooling) or an electric heat element (for heating), and then delivers the conditioned air back into the supply ductwork.

The unit's multi-position design allows for flexible installation in various residential or commercial settings. It is factory-configured for up-flow and horizontal right-hand discharge, with field modifications required for down-flow or horizontal left-hand discharge applications.

Usage Features

  • Multi-Position Installation: The CBX27UH can be installed in up-flow, down-flow, horizontal right-hand, or horizontal left-hand configurations, offering versatility to suit different building layouts and space constraints.
  • Optional Electric Heat: The unit is designed to integrate with an optional field-installed electric heat section, providing supplementary or primary heating capabilities.
  • Blower Speed Adjustment: The blower motor speed can be adjusted via speed taps on the low voltage terminal strip in the control section. This allows for optimization of airflow (CFM) based on the specific system requirements, such as matching nominal tonnage or adjusting for high static applications. The motor is programmed with a 45-second delay-off on most speed taps, ensuring controlled shutdown.
  • Condensate Management: The unit includes a main drain and an overflow drain to manage condensate produced during cooling operations. Proper installation of a drain trap and routing of the drain lines are crucial to prevent water blow-off problems and ensure efficient condensate removal. For horizontal applications, a secondary drain pan is recommended, and for down-flow orientations, the overflow drain must be connected to an overflow drain line.
  • Refrigerant Line Connections: The unit is equipped with factory-installed, internally mounted check/expansion valves and is designed for brazing connections to refrigerant lines. Nitrogen purging during brazing is essential to prevent oxidation and moisture introduction into the system.
  • Electrical Connections: The unit requires line voltage power supply from a circuit breaker and low voltage wiring from an outdoor unit and thermostat. Separate knock-outs are provided for 24V low voltage and line voltage wiring to prevent interference. Wiring must conform to national and local electrical codes.
  • Air Filtration: The unit includes a filter for air purification. Filters should be inspected regularly and cleaned or replaced as needed to maintain proper air handler operation.

Maintenance Features

  • Easy Access for Service: Access panels are designed for easy removal, facilitating maintenance and service of internal components such as the blower and coil assemblies.
  • Filter Maintenance: Filters are accessible and can be removed for cleaning or replacement. Reusable filters can be washed with water and mild detergent, while throw-away filters should be replaced when dirty. Regular filter inspection (monthly) is recommended to ensure proper airflow and unit efficiency.
  • Condensate Drain Inspection: It is important to periodically check the drain pan plugs and drain holes to ensure they are fully open and free of debris. This prevents blockages that could lead to water blow-off issues.
  • Cabinet Insulation Repair: The unit's cabinet contains insulation to maintain thermal integrity. If the insulation becomes wet, damaged, separated, or torn, it must be repaired or replaced. Areas of condensation on the cabinet surface indicate a need for insulation repair. Repair involves cutting an X pattern, peeling open, applying all-purpose glue, and pressing the tabs back, ensuring full coverage to prevent air pockets and sweating. For foil-faced insulation, any cuts or tears should be taped with a similar foil-faced tape.
  • Static Pressure Measurement: The unit allows for static pressure measurement using a manometer, which helps in diagnosing airflow issues and ensuring optimal performance. Tap locations are provided for this purpose.

Lennox CBX27UH Specifications

General IconGeneral
TypeAir Handler
BrandLennox
ModelCBX27UH
EfficiencyUp to 16 SEER
RefrigerantR-410A
Heating CapacityVaries by model
Nominal Heating CapacityVaries by model
AirflowUp to 2000 CFM
Coil TypeAluminum
Voltage208/230V
Sound LevelQuiet operation
HeightVaries by model
WidthVaries by model
LengthVaries by model
WeightVaries by model
Nominal Cooling Capacity1.5 to 5 tons
Motor TypeECM
Cabinet ConstructionHeavy-gauge, painted steel
InsulationFully insulated