Page 1
2002 Lennox Industries Inc.
Corp. 0206−L3
CBX32MV
Service Literature
Revised 02−2010
CBX32MV (HFC−410A) SERIES UNITS
TABLE OF CONTENTS
Introduction 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Number Identification.. 2. . . . . . . . . . . . . . . . . . .
Specifications / Electrical Data 2. . . . . . . . . . . . . . . . . .
Blower Performance 4. . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Arrangement 10. . . . . . . . . . . . . . . . . . . . . . . . . . . .
I− Application 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
II− Unit Components 11. . . . . . . . . . . . . . . . . . . . . . . . . . .
III− Troubleshooting the Variable Speed Motor 15. . . . .
IV− Optional Electric Heat 17. . . . . . . . . . . . . . . . . . . . . . .
V− Optional Humidity Control 23. . . . . . . . . . . . . . . . . . . .
VI− Configuration Modifications 30. . . . . . . . . . . . . . . . . .
VII− Start Up Operation 34. . . . . . . . . . . . . . . . . . . . . . . . .
VIII− Operating Characteristics 35. . . . . . . . . . . . . . . . . .
XI− Maintenance 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
X− Wiring and Operation Sequence 36. . . . . . . . . . . . . .
Introduction
The CBX32MV is a high efficiency residential split system
blower/coil featuring a variable speed motor controlled by an
electronic blower drive control (BDC).
CBX32MV series units are designed to be matched with
Lennox two-speed or single-speed HFC−410A condensing
units and heat pumps. Several models are available in sizes
ranging from 1.5 through 5 tons. All units are equipped with
factory installed check and expansion valve for cooling or heat
pump applications.
Electric heat is available in several voltages and KW sizes,
and can be field installed in the cabinet.
Some CBX32MV applications may include the optional
Lennox ComfortSense
®
7000, SignatureStatt or
Efficiency Plus Comfort Management Control (CCB1). The
purpose of both controls is to vary indoor blower speed in
response to indoor dehumidification demand. When a
two-speed outdoor unit is used, compressor speed can
also be controlled by the SignatureStat or CCB1 in
response to indoor dehumidification demand.
Information contained in this manual is intended for use by
experienced HVAC service technicians only. All
specifications are subject to change. Procedures outlined
in this manual are presented as a recommendation only
and do not supersede or replace local or state codes.
WARNING
Electric shock hazard. Can cause injury
or death. Before attempting to perform
any service or maintenance, turn the
electrical power to unit OFF at discon-
nect switch(es). Unit may have multiple
power supplies.
ELECTROSTATIC DISCHARGE (ESD)
Precautions and Procedures
CAUTION
Electrostatic discharge can affect electronic
components. Take precautions during unit instal-
lation and service to protect the unit’s electronic
controls. Precautions will help to avoid control
exposure to electrostatic discharge by putting
the unit, the control and the technician at the
same electrostatic potential. Neutralize electro-
static charge by touching hand and all tools on an
unpainted unit surface before performing any
service procedure.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBX32MV Series and is the answer not in the manual?

Lennox CBX32MV Series Specifications

General IconGeneral
RefrigerantR-410A
CabinetGalvanized Steel
StagesVariable
ConfigurationUpflow/Horizontal
Product TypeAir Handler
SeriesCBX32MV
Nominal Cooling Capacity (BTU/h)18, 000 - 60, 000
Airflow (CFM)600 - 2, 000
Motor TypeECM
Voltage208/230V
Depth (in.)21
Blower MotorVariable Speed
CoilAluminum

Summary

BDC3 Blower Control Board (A15)

Jumper Settings for Speed Selection

Details on selecting blower speed taps using jumper pins.

Variable Speed Motor Troubleshooting

Troubleshooting Recommendations and Moisture Check

General recommendations and steps for motor troubleshooting and moisture checks.

Motor Check Procedures

Cooling and Heating Speed Checks

Procedures for checking motor operation during cooling and heating modes.

Optional Electric Heat (ECB2931)

Matchups, Ratings, and Component Details

Details on electric heat matchups, ratings, and components.

Optional Humidity Control (A20)

Operating Sequence Tables

CCB1 and Outdoor Unit Operating Sequences

Typical operating sequences for CCB1 with two-speed outdoor units.

SignatureStat Operating Sequences

Typical operating sequences for SignatureStat thermostats.

Start-Up and Operation

Preliminary Checks and Basic Operation

Initial checks before start-up and basic cooling/heating operation.

Maintenance

Filters, Blower, Electrical, and Insulation Checks

Routine maintenance checks for filters, blower, electrical, and insulation.

Wiring Schematics and Operation Sequence

Wiring Diagrams and Blower Speed Selection

Wiring diagrams and recommended blower speed tap selection chart.

Single Phase Unit Operation Sequence

Sequence of operation for single-phase units during heating and cooling.

Electric Heat Operation Sequences