Lists contents of the package and initial inspection.
Provides a general overview of the unit and installation.
Warns about injury from improper handling of heavy units.
Covers refrigerant control, system matching, and code adherence.
Alerts to flammable vapors and condensation issues in unconditioned spaces.
Details clearances for accessibility, service, and combustible materials.
Instructions for configuring the unit for upflow air discharge.
General notes for horizontal installations.
Specific steps for right-hand horizontal air discharge.
Field modifications required for left-hand horizontal air discharge.
Information on ordering kits and specific installation requirements for downflow.
Proper installation of primary and secondary drain lines, traps, and sloping.
When a secondary drain pan is required and its specifications.
Detailed steps for connecting drain lines and testing.
Guidelines for supply/return duct connections and filter sizing.
Connecting supply air duct and return air flanges.
Safety and procedural instructions for brazing refrigerant lines.
Guidance on routing, insulating, and protecting refrigerant lines from damage.
Step-by-step guide for making brazed connections with nitrogen purge.
Instructions for sealing the cabinet to prevent moisture ingress.
Safety warnings and guidelines for making electrical connections.
Further details on routing wires and grounding.
Procedure to convert the unit from 240VAC to 208VAC.
Illustrates the wiring for electric heat components and controls.
Diagrams showing thermostat wiring for various system types.
Explanation of the BDC3 control features and jumpers.
How to select and adjust blower speed settings using jumpers.
Performance table for CBA25UHV-018 unit, listing CFM at various settings.
Performance table for CBA25UHV-024 unit, listing CFM at various settings.
Performance table for CBA25UHV-030 unit, listing CFM at various settings.
Performance table for CBA25UHV-036 unit, listing CFM at various settings.
Performance table for CBA25UHV-042 unit, listing CFM at various settings.
Table detailing system response to thermostat and outdoor unit conditions.
Sequences for two-stage systems including cooling and heat.
Explains the function of heat and delay jumpers for fan operation.
Pre-start-up checks and operational testing for system verification.
Routine maintenance tasks including filter inspection and replacement.
Instructions for repairing or replacing damaged cabinet insulation.
Guidelines for using the unit during building construction.
Recommendations for professional cleaning and maintenance of the coil.
Checklist for verifying installation and performance in upflow mode.
Checklist for verifying installation and performance in horizontal mode.