EasyManuals Logo

Lennox CBA25UHV User Manual

Lennox CBA25UHV
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Page 10
NOTE - When installing refrigerant lines longer than 50
feet, see the Lennox Refrigerant Piping Design and Fab-
rication Guidelines, CORP. 9351-L9, or contact Lennox
Technical Support Product Applications for assistance.
To obtain the correct information from Lennox, be sure to
communicate the following information: Model and capac-
ity.
1 - Route the suction and liquid lines from the ttings
on the indoor coil to the ttings on the outdoor unit.
Run the lines in a direct path, avoiding unnecessary
turns and bends.
2 - Make sure that the suction line is insulated over the
entire exposed length and that neither suction nor
liquid lines are in direct contact with oors, walls,
duct system, oor joists, or other piping.
3 - To avoid damaging the rubber grommets in the
cabinet while brazing, slide the rubber grommets
over the refrigerant lines until they are away from
the heat source.
NOTE - Place wet rags against piping plate and around
suction line connections.
4 - Connect the suction and liquid lines to the evaporator
coil. Take care to protect the cabinet and internal
components as detailed in gure 10.
5 - Braze using an alloy of silver or copper and
phosphorus with a melting point above 1,100°F
(593°C).
NOTE - Do not use soft solder.
6 - Allow refrigerant pipes to cool to room temperature.
NOTE - Make sure to route copper refrigerant tubing away
from sharp edges and make sure that it does not touch
other metal surfaces. This prevents damage caused by
vibration or metal-on-metal contact.
7 - Reinstall the rubber grommets into the refrigerant
piping panel.
NOTE - Make sure expansion valve capillary tube is not
touching metal edges or copper tubing.
8 - Make sure outdoor unit has been placed according
to the Installation Instructions and is connected to
the refrigerant lines

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CBA25UHV and is the answer not in the manual?

Lennox CBA25UHV Specifications

General IconGeneral
TypeAir Handler
ModelCBA25UHV
BrandLennox
EfficiencyUp to 16 SEER
RefrigerantR-410A
Nominal Voltage208/230V
Width21 inches
CompatibilityCompatible with Lennox outdoor units
Nominal Cooling Capacity1.5 to 5 tons
Motor TypePSC or ECM
Airflow RangeUp to 2000 CFM
MotorVariable Speed Motor