13ACC
Service Literature
13ACC SERIES UNITS
The 13ACC is a residential splitsystem condensing unit
with SEER ratings up to 14.80. The series is designed for
use with expansion valves (TXV) and RFC. All 13ACC units
utilize scroll compressors.
13ACC condensing units are available in 2, 21/2, 3, 3 1/2, 4
and 5 ton capacities. All major components (indoor blower
and coil) must be matched according to Lennox recommen
dations for the compressor to be covered under warranty.
Refer to the Engineering Handbook for approved system
matchups.
Information contained in this manual is intended for use by
qualified service technicians only. All specifications are subject
to change.
This manual is divided into sections which discuss the
major components, refrigerant system, charging proce
dure, maintenance and operation sequence.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person
al injury or loss of life. Installation and service must
be performed by a qualified installer or service
agency.
WARNING
Refrigerant can be harmful if it is inhaled. Refrigerant
must be used and recovered responsibly.
Failure to follow this warning may result in person
al injury or death.
TABLE OF CONTENTS
General 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Components 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
II Refrigerant System 6. . . . . . . . . . . . . . . . . . . . . . . . . . .
III Charging 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IV Maintenance 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V Wiring and Operating Sequence 12. . . . . . . . . . . . . . .
ELECTROSTATIC DISCHARGE (ESD)
Precautions and Procedures
CAUTION
Electrostatic discharge can affect electronic
components. Take precautions during unit instal
lation and service to protect the unit’s electronic
controls. Precautions will help to avoid control
exposure to electrostatic discharge by putting
the unit, the control and the technician at the
same electrostatic potential. Neutralize electro
static charge by touching hand and all tools on an
unpainted unit surface before performing any
service procedure.
Question and Answer IconNeed help?

Do you have a question about the Lennox 13ACC-036 and is the answer not in the manual?

Lennox 13ACC-036 Specifications

General IconGeneral
Model13ACC-036
Blower TypeMulti-speed
RefrigerantR-410A
Nominal Airflow1200 CFM
Motor TypePSC
Phase1
Cooling Capacity36, 000 BTU
Voltage208/230V

Summary

I - UNIT COMPONENTS

II - REFRIGERANT SYSTEM

III - CHARGING

C - Evacuating the System

Details the steps for properly evacuating the system using a vacuum pump and gauge manifold.

D - Charging

Explains how to charge the condensing unit based on outdoor temperature and metering device.

Weighing in the Charge Fixed Orifice or TXV Systems – Outdoor Temp < 65°F (18°C)

Procedure for weighing in refrigerant charge for fixed orifice/TXV systems in cooler temperatures.

Expansion Valve Systems Charging Using the Approach Method TXV Systems - Outdoor Temp. > 65°F (18°C)

Method for charging TXV systems using approach temperature when outdoor temp is above 65°F.

Charging Using the Subcooling Method TXV & Fixed Orifice Systems – Outdoor Temp. > 65°F (18° C)

Method for charging TXV/fixed orifice systems using subcooling when outdoor temp is above 65°F.

IV - MAINTENANCE

V - WIRING DIAGRAMS AND SEQUENCE OF OPERATION

Related product manuals