Do you have a question about the Lennox ELXA Series and is the answer not in the manual?
Product Type | Air Handler |
---|---|
Series | ELXA |
Cooling Capacity | 1.5 to 5 tons |
Motor Type | ECM |
Voltage | 208/230V |
Warranty | 5-Year Limited Warranty on covered components |
Blower Motor | ECM |
General unit specifications including tonnage and blower type.
Details refrigerant line sizes, condensate drain, and coil specifications.
Specifies blower wheel diameter, width, and filter size.
Lists available blower motor and drive kits and their factory installation status.
Details optional cabinet features like Corrosion Protection and Float Switch.
Lists available control system options like BACnet modules and sensors.
Lists available electric heat kits by size, voltage, and catalog number.
Details standard and high-performance economizers and their controls.
Covers air filters and CO2 sensors for improving indoor air quality.
Lists specific refrigerant system accessories like check valve kits.
Provides blower performance data for the EL072XA model at various air volumes and pressures.
Details blower performance for the EL090XA model across different air volumes and static pressures.
Presents blower performance data for the EL120XA model for various air volumes and static pressures.
Lists blower performance data for the EL150XA model at different air volumes and static pressures.
Details blower performance data for the EL180XA model across various air volumes and static pressures.
Provides blower performance data for the EL240XA model at different air volumes and static pressures.
Lists total resistance for accessories for EL072-090XA models at various air volumes.
Details total resistance for accessories for EL120-150XA models at various air volumes.
Provides total resistance for accessories for EL180-240XA models at various air volumes.
Explains the VFD's role in controlling blower speed based on demand.
Describes the function of the economizer relay K43 in controlling the economizer.
Refers to specifications for blower motor B3 and its drive.
Details terminal blocks TB1 and TB13 for field wiring and VFD connections.
Explains the condensate overflow prevention system using relay K220 and switch S149.
Describes the function of freezestats S49 and S50 in preventing evaporator coil icing.
Explains the role of relay K232 in protecting the inverter and blower operation.
Details the VFD control board A183 and its connection to the thermostat for blower speeds.
Step-by-step guide for adjusting air volume via the blower pulley system.
Explains the composition and operation of electric heating elements.
Describes contactors K15 and K16 for energizing heating elements.
Explains the function of sequencer relays K32 in controlling heat stages.
Details the role of relays K9 and K19 in electrically isolating 24V components.
Describes the purpose of fuses F3 and F4 for protecting heating elements and the blower.
Explains the function of transformer T2 in providing 24VAC power.
Details primary (S15) and secondary (S20) high temperature limits for safety.
Explains how the inverter controls blower speed for energy efficiency.
Guides on setting the blower pulley for maximum CFM delivery.
Describes how to set the blower to low speed for ventilation to save energy.
Details setting minimum damper positions for occupied mode with economizers.
Provides steps for troubleshooting the LVC2 VFD control board.
Identifies terminal designations on the LVC2 board for VFD inputs and thermostat connections.
Provides instructions for verifying proper blower operation and VFD output.
Details the blower operation sequence for cooling modes, including stage changes.
Describes the blower operation sequence for heating modes.
Explains the sequence for 1-stage electric heat operation, including control relays.
Details the sequence for 2-stage electric heat for both AC and heat pump units.
Describes the 2-stage electric heat sequence for 50kW units in Y volt configuration.