WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
WARNING
Electric shock hazard! - Disconnect all power
supplies before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
To prevent serious injury or death:
1. Lock-out/tag-out before performing maintenance.
2. If system power is required (e.g., smoke detector
maintenance), disable power to blower, remove fan
belt where applicable, and ensure all controllers
and thermostats are set to the “OFF” position before
performing maintenance.
3. Always keep hands, hair, clothing, jewelry, tools, etc.
away from moving parts.
Table of Contents
SPECIFICATIONS .......................................................... 2
BLOWER DATA ..............................................................4
I - UNIT COMPONENTS ..............................................19
II − REFRIGERATION SYSTEM ..................................20
III − BLOWER SPEED & BELT TENSION ....................20
IV − Electric Heat Components ....................................21
Supply Air Inverter Startup............................................22
Verify Proper Operation ................................................ 23
Sequence of Operation ................................................24
ELXA
6 – 20 TONS
Service Literature
UNIT INFORMATION
100069
April 20, 2023
ELXA SERIES AIR HANDLER UNITS
ELXA series blower−coil units are designed for upow or
horizontal air and indoor applications only. ELXA blower
units are available in six models; 072, 090, 120, 150, 180
and 240. The units match up with ELXC condensing units
and ELXP heat pump units charged with HFC−410A re-
frigerant.
Information and specications contained in this manual
are subject to change. Procedures outlined in this manual
are presented as a recommendation only and do not su-
persede or replace local or state codes.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
Question and Answer IconNeed help?

Do you have a question about the Lennox EL072XASS and is the answer not in the manual?

Lennox EL072XASS Specifications

General IconGeneral
ModelEL072XASS
TypeAir Handler
RefrigerantR-410A
Phase1
Voltage208/230V
Filter TypeStandard

Summary

Blower Data

Blower Performance Tables

Performance data for various ELXA models.

Optional Electric Heat Data

EL072 XA Electric Heat Data

Electrical requirements for EL072XA electric heat.

EL090 XA Electric Heat Data

Electrical requirements for EL090XA electric heat.

EL120 XA Electric Heat Data

Electrical requirements for EL120XA electric heat.

EL150 XA Electric Heat Data

Electrical requirements for EL150XA electric heat.

EL180 XA Electric Heat Data

Electrical requirements for EL180XA electric heat.

EL240 XA Electric Heat Data

Electrical requirements for EL240XA electric heat.

Unit Components

Variable Frequency Drive (VFD)

VFD for blower speed control and energy efficiency.

Freezestats

Low-temperature sensors to prevent evaporator coil icing.

VFD Control Board

Board A183 for VFD and blower speed management.

Supply Air Inverter Startup

T3 EH Electric Heat Sequence of Operation