WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
WARNING
Electric shock hazard! - Disconnect all power
supplies before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
To prevent serious injury or death:
1. Lock-out/tag-out before performing maintenance.
2. If system power is required (e.g., smoke detector
maintenance), disable power to blower, remove fan
belt where applicable, and ensure all controllers
and thermostats are set to the “OFF” position before
performing maintenance.
3. Always keep hands, hair, clothing, jewelry, tools, etc.
away from moving parts.
Table of Contents
SPECIFICATIONS .......................................................... 2
BLOWER DATA ..............................................................4
I - UNIT COMPONENTS ..............................................19
II − REFRIGERATION SYSTEM ..................................20
III − BLOWER SPEED & BELT TENSION ....................20
IV − Electric Heat Components ....................................21
Supply Air Inverter Startup............................................22
Verify Proper Operation ................................................ 23
Sequence of Operation ................................................24
ELXA
6 – 20 TONS
Service Literature
UNIT INFORMATION
100069
April 20, 2023
ELXA SERIES AIR HANDLER UNITS
ELXA series blower−coil units are designed for upow or
horizontal air and indoor applications only. ELXA blower
units are available in six models; 072, 090, 120, 150, 180
and 240. The units match up with ELXC condensing units
and ELXP heat pump units charged with HFC−410A re-
frigerant.
Information and specications contained in this manual
are subject to change. Procedures outlined in this manual
are presented as a recommendation only and do not su-
persede or replace local or state codes.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
Question and Answer IconNeed help?

Do you have a question about the Lennox EL180XASD and is the answer not in the manual?

Lennox EL180XASD Specifications

General IconGeneral
BrandLennox
ModelEL180XASD
CategoryAir Handlers
LanguageEnglish

Summary

UNIT INFORMATION

OPTIONS AND ACCESSORIES

BLOWER PERFORMANCE DATA

EL072XA Blower Performance

Performance data for EL072XA blower.

EL090XA Blower Performance

Performance data for EL090XA blower.

EL120XA Blower Performance

Performance data for EL120XA blower.

EL150XA Blower Performance

Performance data for EL150XA blower.

EL180XA Blower Performance

Performance data for EL180XA blower.

EL240XA Blower Performance

Performance data for EL240XA blower.

EL072XA Static Pressure Performance

Blower performance data based on static pressure.

EL090XA Static Pressure Performance

Blower performance data based on static pressure.

EL120XA Static Pressure Performance

Blower performance data based on static pressure.

EL150XA Static Pressure Performance

Blower performance data based on static pressure.

EL180XA Static Pressure Performance

Blower performance data based on static pressure.

EL240XA Static Pressure Performance

Blower performance data based on static pressure.

BLOWER SPECIFICATIONS

ACCESSORY AIR RESISTANCE

OPTIONAL ELECTRIC HEAT DATA

UNIT COMPONENTS

BLOWER SPEED & BELT TENSION

Air Volume Adjustment Procedure

Procedure for adjusting blower speed and belt tension.

ELECTRIC HEAT COMPONENTS

SUPPLY AIR INVERTER STARTUP

Setting Maximum Blower CFM

Procedure to set maximum blower CFM.

LVC2 BOARD TROUBLESHOOTING

LVC2 Board Troubleshooting Steps

Troubleshooting steps for the LVC2 board.

LVC2 BOARD TERMINAL DESIGNATIONS

VERIFYING PROPER OPERATION

SEQUENCE OF OPERATION

EL072/240XA Cooling Sequence

Cooling sequence for EL072/240XA units.

EL072/240XA Heating Sequence

Heating sequence for EL072/240XA units.

WIRING DIAGRAM - BLOWER

WIRING DIAGRAM - THERMOSTAT

T3EH ELECTRIC HEAT SEQUENCE

WIRING DIAGRAM - ELECTRIC HEAT

T3EH ELECTRIC HEAT SEQUENCE

Related product manuals