14ACX - 1.5 to 5 Ton Air Conditioner / Page 100
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110E60C 7782805
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110XE60C 7627023
14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL195UH090XE48C 7782806
14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL195UH110XE60C 7782807
14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL296UH090XE48C 7627026
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH090XV36C 7782808
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL296UH090XV48C 7782809
14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL296UH110XE60C 7627029
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH110XV48C 7782810
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C SLP98UH090XV36C 7627032
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C SLP98UH090XV48C 7627035
14ACXS036-230A TXV 33,800 15.50 12.50 CX34-36C SLP98UH110XV60C 7628477
14ACXS036-230A TXV 33,000 14.00 11.50 CX34-36C 7782804
14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045E36A 7782812
14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045XE36A 7627044
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070V36A 7782811
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070XV36A 7627041
14ACXS036-230A TXV 34,200 14.50 12.20 CX34-38A 7627038
14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070E36B 7627050
14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070XE36B 7782815
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090E48B 7627053
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090XE48B 7782816
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH045XE36B 7627056
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH070XE36B 7627059
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH045XE36B 7782817
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH045XV36B 7627062
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH070XE36B 7782818
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH070XV36B 7782819
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V36B 7782813
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V48B 7627047
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090XV48B 7782814
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B SLP98UH070XV36B 7627065
14ACXS036-230A TXV 34,200 14.25 12.20 CX34-38B 7626099
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070E36B 7783211
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070XE36B 7628486
14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090E48B 7783212
14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090XE48B 7628489
14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL195UH045XE36B 7783213
14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL195UH070XE36B 7783214
14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL296UH045XE36B 7628493
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH045XV36B 7783215
14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL296UH070XE36B 7628496
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH070XV36B 7628498
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V36B 7628480
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V48B 7783210
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090XV48B 7628483
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 SLP98UH070XV36B 7783216
14ACXS036-230A TXV 33,000 14.00 11.50 CX34-42 7783209
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070E36B 7782822
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.