14ACX - 1.5 to 5 Ton Air Conditioner / Page 100
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110E60C 7782805
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110XE60C 7627023
14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL195UH090XE48C 7782806
14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL195UH110XE60C 7782807
14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL296UH090XE48C 7627026
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH090XV36C 7782808
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL296UH090XV48C 7782809
14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL296UH110XE60C 7627029
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH110XV48C 7782810
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C SLP98UH090XV36C 7627032
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C SLP98UH090XV48C 7627035
14ACXS036-230A TXV 33,800 15.50 12.50 CX34-36C SLP98UH110XV60C 7628477
14ACXS036-230A TXV 33,000 14.00 11.50 CX34-36C 7782804
14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045E36A 7782812
14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045XE36A 7627044
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070V36A 7782811
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070XV36A 7627041
14ACXS036-230A TXV 34,200 14.50 12.20 CX34-38A 7627038
14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070E36B 7627050
14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070XE36B 7782815
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090E48B 7627053
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090XE48B 7782816
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH045XE36B 7627056
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH070XE36B 7627059
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH045XE36B 7782817
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH045XV36B 7627062
14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH070XE36B 7782818
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH070XV36B 7782819
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V36B 7782813
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V48B 7627047
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090XV48B 7782814
14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B SLP98UH070XV36B 7627065
14ACXS036-230A TXV 34,200 14.25 12.20 CX34-38B 7626099
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070E36B 7783211
14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070XE36B 7628486
14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090E48B 7783212
14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090XE48B 7628489
14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL195UH045XE36B 7783213
14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL195UH070XE36B 7783214
14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL296UH045XE36B 7628493
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH045XV36B 7783215
14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL296UH070XE36B 7628496
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH070XV36B 7628498
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V36B 7628480
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V48B 7783210
14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090XV48B 7628483
14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 SLP98UH070XV36B 7783216
14ACXS036-230A TXV 33,000 14.00 11.50 CX34-42 7783209
14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070E36B 7782822
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.